CHROMA 62060D-600 Programmable Bidirectional DC Power Supply (0–600V; ±40A; ±6000W)
- Bidirectional source/load specifications
+ Supply/absorption voltage: 0–600 V
+ Supply/absorption current: ±40 A
+ Supply/absorption power: ±6000 W
+ Minimum load voltage (at max current): 30 V
- Stability
+ Source regulation
Voltage: ±0.01% F.S.
Current: ±0.05% F.S.
+ Load regulation
Voltage: ±0.02% F.S.
Current: ±0.1% F.S.
- Measurement
+ Voltage measurement
Range: 120V / 600V
Accuracy: ±(0.05% + 0.05% F.S.)
+ Current measurement
Range: 8A / 40A
Accuracy: ±(0.1% + 0.1% F.S.)
- Response time
Rise time (full load): 20 ms
Rise time (no load): 10 ms
Fall time (full load): 20 ms
Fall time (no load): 10 ms
- Drift
+ 30 minutes
Voltage: 0.04% Vmax
Current: 0.06% Imax
+ 8 hours
Voltage: 0.02% Vmax
Current: 0.04% Imax
- Temperature coefficient
Voltage: 0.04% Vmax / °C
Current: 0.06% Imax / °C
- Input specifications
+ AC input: 3-phase, 3-wire + ground (no neutral)
3-phase 200Vac–220Vac ±10% (no neutral)
3-phase 380Vac–480Vac ±10% (no neutral)
(67% output power at 200–220Vac input, 100% output power at 380–480Vac input)
+ AC frequency range: 47–63 Hz
+ Power factor: > 0.97
- General specifications
+ Maximum remote sense compensation: 2% full-scale voltage per wire (4% total)
+ Operating temperature range: 0°C – 40°C
+ Storage temperature range: -25°C – 70°C
+ Dimensions (H x W x D): 133 × 428 × 730 mm / 5.23 × 16.85 × 28.74 in
+ Weight: 27 kg / 59.5 lbs
- Standard accessories: Main unit