인증된 전문가에게 직접 연결
인증된 전문가에게 직접 연결
Standards
IEC 61252:1993 +AMD1:2000 Personal Sound Exposure Meters
IEC 61252 Ed 1.1 (2002-03) Personal Sound Exposure Meters
ANSI S1.25:1991 (R2017) Personal Noise Dosimeters
IEC 61260-1:2014 Class 2 (Octave Bands from 63Hz to 8kHz)
ANSI S1.11-2014 Class 2 (Octave Bands from 63Hz to 8kHz)
Measurement Range
RMS Range – 60 dB(A) to 140 dB(A)
Peak Range – 80 dB(C) to 143 dB(C)
Octave Bands – 70 dB(A) to 140 dB(A)
Measurement Functions
4 Simultaneous Independent Integrator Channels
2 Simultaneous Independent Peak Channels
1:1 Octave Bands (63Hz to 8kHz)
Overall Measurement Parameters
Measurement duration, Start time & date, Instrument serial number & name
Calibration information (field & factory calibration), Overload & Tamper sensor detection
Overall Integrator Parameters
Average Integrated Sound Level (Leq/LAVG), Time Weighted Average (LEP,d/LEX,8/TWA)
Sound Exposure & Estimated Sound Exposure, % Dose & Estimated % Dose, ULT Duration
SPL Max Level & Time, SPL Min Level
Overall Peak Channel Parameters
Overall LPeak level for each channel (Up to 2 channels)
Overall Octave Band Parameters
Overall unweighted Leq for each octave band (63Hz to 8kHz)
Communication
Bluetooth® Wireless communication to the doseBadge5 dBControl
Bluetooth® Wireless communication to the dBLink App (Android & iOS)
USB download to NoiseTools via the doseBadge5 Dock
Integrator Channel Options
Channel name – Preset or user defined
Exchange rate – 3, 4 or 5 dB
Criterion Level – 80 dB to 100 dB in 1 dB steps
Criterion Time – 1 hr to 24 hrs in 1hr steps
Threshold Level – None, 70 dB to 100 dB n 1dB steps
Time Weighting – Fast, Slow or None
Frequency Weighting – A, C or Z
ULT Level – 70 dB to 140 dB in 1 dB stepsULT Time Weighting – None, Fast or Slow
ULT Freq. Weighting – A,C, or ZSPL Max Time Weighting – Fast or Slow
SPL Max Freq Weighting – A,C or Z
LED Threshold Trigger – User selectable channel with user selectable % Dose trigger levels (75% to 100% in 5% steps)
Peak Channel Options
Frequency weighting – A,C or Z (2 channels)
Calibration
Automatic detection of external acoustic calibration
User configurable calibration level (typically 114dB or 94dB)
Data Logging
1 second or 1-minute time history data (user selectable)
Memory
Up to 80 hours of Time History Data for each channel including 1:1 Octave Bands
Up to 40 individual measurements
Maximum duration of any single measurement: 24 hours
doseBadge5 Dimensions
66 mm x 43 mm x 53 mm (excluding clips)
2.53” x 1.69” x 2.01” (excluding clips) 85 g/2.9 oz