Comet M1220 온도, 습도 데이터 로거 (AC adapter 230Vac/5Vdc)

ModelM1220
P/NM1220
문의하기
안전한 결제
품질 보장
간편 교환 및 반품
배송 가능

Measured value: Temperature, Relative humidity, Counted values (Dew point…)

Temperature sensor - external probe PT1000:

  Measuring range: -200 to +600 °C

  Accuracy: ±0.2 °C (-200 to +100 °C);

                   ±0.2 % from reading from +100 to +600 °C

  Resolution: 0.1 °C

Temperature + humidity sensor - external probe T+RH DIGI:

  Measuring range: according to the connected probe Digi/M

  Accuracy: according to the connected probe Digi/M

  Resolution: 0.1 °C

Dew point:

  Measuring range: according to the connected probe Digi/M

  Accuracy: according to the connected probe Digi/M

  Resolution: 0.1 °C

Temperature sensor - Thermocouple K, N:

  Measuring range: -200 to +1300 °C

  Accuracy: ± 0.3 % from the Measured value + 1.5 °C

  Resolution: 0.1 °C

Temperature sensor - Thermocouple J:

  Measuring range: -200 to +750 °C

  Accuracy: ± 0.3 % from the Measured value + 1.5 °C

  Resolution: 0.1 °C

Temperature sensor - Thermocouple S:

  Measuring range: 0 to +1700 °C

  Accuracy: ± 0.3 % from the Measured value + 1.5 °C

  Resolution: 0.1 °C

Temperature sensor - Thermocouple B:

  Measuring range: 100 to +1800 °C

  Accuracy: ± 0,3 % from the Measured value + 1 °C in the range +300 to +1800 °C

  Resolution: 0.1 °C

Temperature sensor - Thermocouple T:

  Measuring range: -200 to +400 °C

  Accuracy: ± 0.3 % from the Measured value + 1.5 °C

  Resolution: 0.1 °C

DC voltage:

  Measuring range: -60 to +140 mV; -18 to +18 mV

  Accuracy: ±100 µV; ±20 µV

  Resolution: 0.1 µV

Operating temperature: -10 to +60 °C

Channels: 4x external temperature probe

Counted values: Dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy

Memory: 1 000 000 values (noncyclic record), 600 000 values (cyclic record)

Recording interval: 1s to 24 hours

Display and alarm refresh: each 10 s

Recording mode: noncyclic - data logging stops after filling the memory

                            cyclic - after filling memory oldest data is overwritten by new

Available temperature units: degrees Celsius, degrees Fahrenheit

  Communication interface: Ethernet, USB, RS232

  Ethernet communication protocols: WWW, SNMPv1, XML, DATALINK

  Alarm protocols E-Mail

  Power: AC adapter 230Vac/5Vdc (neccessary for Ethernet interface)

  Battery life: 3 - 4 weeks

  Protection class: IP20

  Dimensions (without connectors): 178 x 95 x 37mm, without attached cables

  Weight (including batteries): approx. 380 g

Included in delivery:

  M1220

  Instruction Manual

  Traceable Calibration Certificate

  3x Rechargeable Battery AA

  Power Supply

  USB Cable

  Wall Holder

  FREE FULL VERSION Analytical Software COMET Vision

  EXTERNAL PROBES ARE NOT Included in delivery

Datasheet


Manual

혜택 소식 받아보기

대량 할인, 도매 가격 업데이트 및 신제품 소식을 이메일로 받아보세요.

구독하면 당사의 서비스 이용약관개인정보 처리방침에 동의하는 것으로 간주됩니다.

빠른 지원

인증된 전문가에게 직접 연결