For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0

CRYSOUND releases Firmware V0.0.41 for CRY8024 and CRY8025: Improvements to SPL calculation and air leak estimation

2026년 11월 25일 13시 48분 02초

CRYSOUND has released Firmware V0.0.41 for the CRY8024 and CRY8025 handheld ultrasonic camera models, part of the SonoCam Pocket series. This update focuses on two key improvements: optimizing the sound pressure level (SPL) calculation for both models and refining the algorithm used to estimate gas leak flow rates on the CRY8025

CRYSOUND Releases Firmware V0.0.41 for CRY8024 and CRY8025: Improved SPL Calculation and Gas Leak Estimation

Applicable Models
CRY8024 & CRY8025 Pro
Shared Upgrade
Optimized SPL Calculation
CRY8025 Exclusive
Leak Quantification Algorithm

What’s New in Firmware V0.0.41 for CRY8024 and CRY8025?

CRYSOUND has released Firmware V0.0.41 for two pocket acoustic imaging camera models, CRY8024 and CRY8025, from the SonoCam Pocket series. This update focuses on two key areas: optimizing Sound Pressure Level (SPL) calculation across both models and refining the gas leak flow rate estimation algorithm on the CRY8025.

CRY8024 & CRY8025 Pro

These changes directly impact how inspection results are analyzed. Specifically, the SPL calculation improvement aims for greater measurement consistency, while the refined leak estimation algorithm enhances the quantitative capabilities of the CRY8025.

Both updates also highlight the distinct application focus between the CRY8024 and the CRY8025 Pro version—particularly when enterprises need to convert leak detection findings into actionable data for energy loss assessments.

64-MEMS Microphone Array Ultrasonic Acquisition & Leak Quantification (Firmware V0.0.41)
COMPRESSED AIR PIPEULTRASONIC LEAK SOURCE64 MEMS MICSFirmware V0.0.41SPL MAP · 5MPCRY8025 PROEST. LEAK RATE1.57 L/minEST. LOSS COST$122.74/yrALGORITHMSPL + LEAK V0.0.41

Schematic illustrating ultrasonic wave capture via the 64-MEMS microphone array, Sound Pressure Level (SPL) heatmap overlay on the 5 MP optical image, and quantitative leak rate calculation on the CRY8025 Pro.

Two Key Refinements in Firmware V0.0.41

1. Optimized SPL Calculation on Both CRY8024 and CRY8025

SPL (Sound Pressure Level) measures acoustic intensity at a given point. In an acoustic imaging camera, this parameter governs how sound sources are processed and rendered on the acoustic heatmap.

With Firmware V0.0.41, CRYSOUND has optimized the SPL calculation algorithm across both the CRY8024 and CRY8025. This refinement improves measurement consistency, making it easier to observe and evaluate acoustic sources.

For routine preventive inspections, consistent readings are critical when technicians need to compare data across multiple inspection cycles or monitor the same asset location over time during maintenance.

2. Refined Leak Flow Rate Estimation Algorithm on CRY8025

Unlike the CRY8024, which focuses on acoustic source detection and localization, the CRY8025 Pro adds the ability to estimate gas leak flow rates and convert them into projected financial losses.

In Firmware V0.0.41, CRYSOUND further refined this leak flow estimation algorithm. This update applies exclusively to the CRY8025 and is not included on the CRY8024.

Quantification provides technicians with an objective basis for prioritizing repairs. Rather than merely logging leak locations, users can reference estimated gas loss volume and annual cost to schedule maintenance effectively.

Note: Displayed figures are estimates. Results depend on system parameters configured on the device and should not be treated as fixed loss rates across all operating conditions.

Gas Leak Quantification Example Using CRY8025

In the update release documentation, CRYSOUND demonstrates a leak inspection case on an industrial compressed air pipeline using the CRY8025. The device screen displays the following results:

Estimated Leak Flow Rate
1.57 L/min
Estimated Annual Loss Cost
122.74 USD/year

These figures represent an illustrative case published by CRYSOUND rather than a standard benchmark for every leak point. Actual costs depend on operating conditions, line pressure, gas properties, and the electricity tariff entered during calculation.

The core value of this capability lies in adding quantitative metrics to maintenance workflows. With estimated flow rates and financial loss data on hand, enterprises gain clear criteria to compare leak severities and prioritize corrective actions.

How Does CRY8025 Detect and Estimate Gas Leaks?

The CRY8025 SonoCam Pocket Pro uses a 64-channel digital MEMS microphone array to capture ultrasonic signals. The unit processes these signals and overlays a color-coded acoustic map onto live imagery from an autofocus 5 MP optical camera.

This visual overlay allows technicians to pinpoint sound sources directly on real-world equipment rather than relying solely on audio cues. Gas leak inspections with the CRY8025 follow a straightforward four-step workflow:

STEP 01
Configure Inspection Parameters

Select leak detection mode on the touchscreen and enter relevant parameters such as gas type, pipeline pressure, and electricity cost. These inputs serve as the baseline for flow rate and financial loss calculations.

STEP 02
Scan the Target Area

Pan the camera across pipelines, valves, fittings, and joints. The acoustic heatmap updates in real time over the optical feed. The CRY8025 supports automatic frequency band selection as well as manual tuning to filter out background noise.

STEP 03
Capture and Evaluate Findings

Once a suspected leak is located, capture photos or record video to document its condition. In quantification mode, the camera displays estimated leak flow rate and projected annual loss cost based on configured parameters.

STEP 04
Transfer Data and Generate Reports

Inspection data can be transferred via Wi-Fi to a mobile device using the Acoustic Link app or exported to PC software for data aggregation, reporting, and ongoing maintenance tracking.

Industrial Applications of CRY8024 and CRY8025 Acoustic Cameras

Beyond compressed air leak detection, CRYSOUND acoustic imaging cameras support a wide range of industrial inspection tasks:

Compressed Air Systems: Inspect pipelines, valves, quick-connect couplings, regulators, and joints prone to leakage. Non-intrusive external scanning lets technicians isolate problem areas without shutting down or disassembling equipment.
Vacuum Systems and Gas Lines: Pinpoint ultrasonic emissions generated at leak points even in environments with high ambient machinery noise.
HVAC and Refrigeration Systems: Locate suspected leaks across cooling circuits and air-conditioning units.
Automotive Manufacturing: Verify sealing integrity around weatherstripping, gaskets, and cabin enclosures.
Electrical Power Systems: Detect and localize partial discharge (PD) activity through high-frequency ultrasonic emissions.

Actual detection performance depends on acoustic source characteristics, inspection distance, ambient environment, and device configuration.

CRY8024 vs. CRY8025 Comparison: Which Model Should You Choose?

Both the CRY8024 and CRY8025 belong to the SonoCam Pocket series, leveraging acoustic imaging to detect and localize sound sources. Key differences lie in leak quantification, PC data analysis, and core operating ranges.

관련 뉴스

Triển lãm "Dây & Cáp điện 2026" - Ngày 1
2026년 11월 25일 14시 31분 19초

Tại gian hàng D02, EMIN mang 4 thiết bị Rohde & Schwarz đến để trưng bày và vận hành trực tiếp: máy phân tích tín hiệu và phổ R&S®FSV3044, máy hiện sóng hiệu năng cao R&S®RTP134, máy phân tích mạng vector R&S®ZNLE4 và máy phân tích mạng vector cầm tay R&S®ZNH18

Checklist of 5 parameters to verify before sourcing plasma
2026년 11월 25일 10시 25분 45초

Some ordering errors only come to light once the equipment arrives at the facility—such as a plasma power source failing to ignite, connectors that do not fit the electrical cabinet, or an inability to communicate with the existing PLC. Such issues often lead to weeks of waiting for replacements, causing production lines to come to a standstill. The following five categories of specifications can help engineers and procurement teams verify requirements before finalizing an order

DC, Pulsed DC, or RF: Selecting a Plasma Source Based on Material and Process
2026년 11월 23일 16시 55분 48초

In sputtering, positive ions (typically Argon) are accelerated toward a target to bombard and dislodge material. A stable ion current can only be maintained if electric charge does not accumulate on the target surface. The simulation below illustrates this principle qualitatively: the blue trace follows the waveform, while the amber-colored bar represents the level of charge accumulated on the target surface

What Do Protection Relays and Relay Testers Do?
2026년 11월 23일 14시 20분 37초

Protection relays help isolate faults and respond to abnormal power-system conditions. Relay testers simulate electrical signals and evaluate whether a protection device responds according to its logic and settings.

혜택 소식 받아보기

대량 할인, 도매 가격 업데이트 및 신제품 소식을 이메일로 받아보세요.

구독하면 당사의 서비스 이용약관 및 개인정보 처리방침에 동의하는 것으로 간주됩니다.

빠른 지원

인증된 전문가에게 직접 연결