For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

Cybertek EM5080M EMI 테스트 수신기 (9kHz~500MHz)

문의하기
안전한 결제
품질 보장
간편 교환 및 반품
배송 가능

Frequency range: 9kHz to 500MHz

Level

Maximum RF level (CW)

RF attenuation≥20dB: 30dBm(=1W)

RF pre-Amplifier off: 30dBm(=1W)

Maximum pulse voltage: RF attenuation≥20dB: 150V

Resolution ratio bandwidth

Analyzer mode: 1 /2 / 3 / 5 / 10 step from 10Hz to 1MHz (- 3dB)

Receiver mode: Standard: 200Hz, 9kHz, 120kHz(–6dB); Newly added 10kHz and 100kHz (-6dB) extra optional

Preselector: Could be turned off in analyzer mode: 15 tunnel fixed filter

Preset amplifier: Can be turn on/off; 9kHz to 1GHz, 20dB gain, uniformed

Test time: Receiver mode; 1ms to 1.5s

Detector: Receiver mode; Peak, quasi-peak, average value

Displayed average noise level:

Receiver mode, uniformed, Average detector, RF attenuation 0dB

Preset Amplifier off.

9kHz<f<150kHz, bandwidth 200Hz: < 0dBμV

150kHz<f<30MHz, bandwidth 9kHz: < 10dBμV

30MHz<f<1GHz, bandwidth 120kHz: < 20dBμV

Preset Amplifier on 

9kHz<f<150kHz, bandwidth 200Hz: < -5dBμV

150kHz<f<30MHz, bandwidth 9kHz: < 0dBμV

30MHz<f<1GHz, bandwidth 120kHz: < 5dBμV

All uncertainty: 9kHz≤f<1GHz; 1.5dB

Power consumption: <100W

Manual


혜택 소식 받아보기

대량 할인, 도매 가격 업데이트 및 신제품 소식을 이메일로 받아보세요.

구독하면 당사의 서비스 이용약관개인정보 처리방침에 동의하는 것으로 간주됩니다.

빠른 지원

인증된 전문가에게 직접 연결