인증된 전문가에게 직접 연결
인증된 전문가에게 직접 연결

EXCITATION SOURCE:
Channels: 1
Frequency Range: 10 Hz – 25 MHz user defined ,within instrument frequency range
Output Voltage (pk-pk into 50 Ohms): User selectable between 10 V (default) and 2.5 V
Output Protection: Short circuit protected
Source Impedance: 50 Ohms
MEASUREMENT CHANNELS
Channels: 2
Sampling: Simultaneous
Frequency Range: 10 Hz – 25 MHz
Max. Sampling Rate: 100 MS/s
Input Impedance: 50 Ohms
Recommended Calibration: 1 year
ACCURACY
Magnitude (guaranteed 20 Hz - 2 MHz):
± 0.1 dB (down to -60 dB)
± 0.5 dB (-60 to -100 dB)
DATA COLLECTION
Test Method: Sweep Frequency
PC Comm: USB/Wireless
Frequency Range: 20 Hz - 2 MHz (default), user defined within instrument frequency range
Number of Points:
1045 points (default)
5000 points max per decade (log)
32,000 points max (linear)
Dynamic Range (20 Hz - 2 MHz): >150 dB
IF Bandwidth: <10% of measurement frequency, adaptive
Point Spacing: Variable, Linear or Logarithmic
DATA DISPLAY/EXPORT/ANALYSIS
Tabulation: Frequency/Magnitude/Phase
Export Formats: CSV/IEC/CIGRE, SFRA v5
Plotting: Frequency vs. Magnitude/Phase/ Impedance/Ratio
Analysis: Difference, Cross-Correlation, Leakage Channel, Ratio
PHYSICAL SPECIFICATIONS
Dimensions: 12.25 x 9.5 x 3.7 in (31 x 24 x 9.4 cm)
Weight: 7 lbs (3.2 kg)
Power Supply: 24 VDC (40 W Universal AC in power supply)
Temperature -25° to + 55°C operating -40° to + 85°C storage
Relative Humidity: 0% to 95% non condensing