What is the unit of measurement of air flow? What device is used to measure it?

2025년 06월 18일 09시 32분 45초

Wind plays an essential role not only in renewable energy production but also in environmental management and meteorological forecasting. To determine wind flow, the use of specialized measuring equipment is indispensable. However, first, let's explore the commonly used wind flow measurement units today through the content of the article below!

What is the nature of air flow?

Airflow is the volume of air moving through a given area in a given period of time. It is usually measured in kilograms (the mass of air passing through a given point in space) in a given time (usually hours). The common unit used to measure airflow is the mass of air passing through each square meter in one second (kg/m²/s). Airflow can also be converted to other units such as air volume per second (m³/s) or air mass per second (kg/s).

This parameter plays a particularly important role in evaluating the operating efficiency of equipment such as fans, air compressors or ventilation systems. In addition, air flow is also a factor of interest in many fields such as wind energy, environmental management and meteorology.

So what units are used to measure wind flow?

As mentioned in the concept section, units of wind flow measurement are divided into two main groups: volumetric and mass. Specifically as follows:

Volume units

l/s (liters per second)

m³/h (cubic meter per hour)

ft³/h (cubic feet per hour)

ft³/min (cubic feet per minute, also known as CFM)

Mass units

kg/s (kilograms per second)

What formula calculates air flow?

The formula for determining wind flow is based on the relationship between wind speed and cross-sectional area through which the wind flows. Specifically, the formula is expressed as follows:

Q = A × V

Where:

Q is wind flow (unit: m³/s)

A is cross-sectional area where the wind passes (unit: m²)

V is wind speed (unit: m/s)

To calculate the wind flow, it is necessary to accurately determine two factors: wind speed and cross-sectional area at the measurement location. Wind speed can be measured by a Kitsuda meter or other specialized measuring devices. The cross-sectional area is determined based on the size of the area through which the wind flows. Once these two parameters are available, simply apply the above formula to calculate the wind flow value at the measurement point.

For example: If the measured wind speed is 10 m/s and the cross-sectional area is 5 m², applying the formula we have:

Q = 5 m² × 10 m/s = 50 m³/s

Thus, the wind flow at that location will be 50 m³/s.

What is an air flow meter?

Air flow measuring devices are used to check the performance of wind systems and ensure they meet technical standards and safety requirements. To measure air flow, people often use wind sensors or wind flow meters. Current devices are often integrated with the function of measuring wind speed. Applied technologies include: measuring by hot wire, measuring by fan blade and measuring cup.

Suggest some best air flow meters

After learning about common wind flow measurement units, if you are looking to buy a flow or wind speed meter for use, you can refer to the following devices:

Anemometer TES-3145

TES-3145 is an anemometer capable of measuring wind flow in the range of 0 to 999900 m³/min / 0.001 m³/min, with an accuracy of ±3% of reading ±1%FS. In addition, the device also integrates functions such as: measuring wind speed, measuring air volume, measuring temperature, humidity and atmospheric pressure. 

TES-3145 can also calculate parameters such as dew point temperature, wet bulb temperature, air cooling temperature, heat index temperature and humidity index. Some outstanding features of the device include:

Instantaneous, average, 2/3 air volume measurement

Wind speed unit selection: meter/second, feet/minute

Relative humidity, temperature, and barometric pressure measurement

Data lock and max/min/average function

Manual data memory and reading function: 99 groups

Tenmars TM-412A Temperature, Speed, Air Flow Meter

TM-412A is a device from the widely known TENMARS brand today. The device allows measuring air flow in two ranges 09999 CMM and 09999 CFM. In addition, the device is also capable of measuring absolute pressure, temperature, humidity and wind speed. 

Advantages of Tenmars TM-412A include: 

High sensitivity 0.4 m/s 

Max/Min/Avg measurement, hold measurement data 

Automatic power off or hard button shutdown 

Data recording with memory up to 99 records 

Easy to use in many different environments while still ensuring work efficiency

Testo 420 Air Velocity and Flow Meter

Testo 420 is capable of measuring air flow in the range of 40 to 4000 m³/h, with an accuracy of ±3% of the measured value + 12 m³/h and a fast response time of just 1 second. The device stands out with many features:

Measurement of velocity, flow, absolute pressure, temperature and humidity

Flexible application in spaces such as offices, shopping malls, hospitals...

Supports Bluetooth connection for measurement at air supply sources in HVAC systems

Auto Zero feature for increased pressure measurement accuracy

Large, backlit display for clear results

Analyze, generate reports on-site and send via email via Bluetooth connection (via app)

Supports point-to-point and time-based average calculations

관련 뉴스

Which products are tested using a -40°C to +150°C thermal shock chamber?
2026년 07월 22일 14시 45분 25초

Automotive circuit boards, sensors, modules, and plastic components can all experience issues after repeated transitions between cold and hot environments. A thermal shock chamber operating from -40°C to +150°C enables the replication of these temperature fluctuations under controlled testing conditions.

Does thermal shock cause damage to electronic components?
2026년 07월 22일 10시 40분 49초

An electronic component may operate stably under constant temperature conditions yet fail after repeated rapid transitions between hot and cold. The issue typically stems not from a specific temperature level, but rather from the rate of temperature change and the number of hot-cold cycles

The rigorous standards behind a multi-million-dollar MRI suite
2026년 07월 21일 14시 54분 01초

An MRI system may be correctly installed and fully connected to the power supply, yet still encounter issues if the surrounding environment fails to meet technical specifications. Electromagnetic interference, RF shielding, power quality, grounding, temperature, humidity, and particulate levels are all factors that may require assessment, depending on the facility's design and the manufacturer's requirements.

Sinusoidal and Random Vibration: A Test Setup Guide for Industrial Engineers
2026년 07월 21일 10시 30분 38초

During the operation of industrial machinery or the transportation of goods, persistent mechanical vibrations inevitably occur; these are a primary cause of material fatigue, loosened connections, and cracking in printed circuit boards (PCBs). To ensure product integrity before delivery to customers, R&D and QA/QC engineers must simulate these dynamic forces using vibration test systems.

Capacities of laboratory centrifuge tubes
2026년 07월 20일 13시 55분 40초

Tubes with capacities of 0.2 ml, 1.5 ml, 15 ml, or 50 ml are commonly found in laboratories, yet each type is associated with specific sample categories and equipment configurations. DNA and RNA samples typically require small-volume microtubes; blood and cell samples often utilize 5 ml or 15 ml tubes; while large-volume processing workflows may require tubes of 50 ml, 100 ml, or greater capacity