EiUK RASI700BIO Portable Gas Analyser for BIOGAS applications (O2 ( 0-25 %), CH4 (0-100%), CO2 (0-100%))

문의하기
안전한 결제
품질 보장
간편 교환 및 반품
배송 가능

O2 measurement (Standard): 

Range: 0 to 25 %

Accuracy: ± 0.2 % Vol

Resolution: ± 0.01 % Vol

CO measurement with H2 Compensation ( Optional): 

Range: 0 to 20000 ppm

Accuracy: ± 10 ppm or ± 5 % of reading up to 4000 ppm; ± 10% of reading from 1000 to 20000 ppm

Resolution: 1 ppm

CO2 %  NDIR   (Standard): 

Range: 0 to 100 %

Accuracy: ± 0.3 % Vol or 3 % of reading

Resolution: 0.0001

CH4%  NDIR  (standard): 

Range: 0 to 100 %

Accuracy: ± 0.2% Vol  or ±  3% of the readings

Resolution: 0.01% Vol

H2S (Optional): 

Range: 0 to 5000 ppm

Accuracy: ± 5 ppm or 5 % reading

Resolution: 1 ppm

Range: 0-to 10000 ppm ( max 50000 ppm short exposure)

Accuracy: ± 50 ppm

Resolution: 1 ppm

H2 (Optional): 

Range: 0-2000 ppm

Accuracy: ± 5 ppm or 5 % reading

Resolution: 1 ppm

Flow measurement ( using pitot tube) (Optional): 

Range: 3 to 100 m/s

Accuracy: ± 1 m/s or 3 % reading

Resolution: ± 0.1 m/s

Pressure measurement ( gauge, vacuum and differential) Standard: 

Range: – 300 to 300 mbar

Accuracy: ± 0.02 mbar

Resolution: ± 0.01 mbar

Temperature & differential temperature ( Type K thermocouple) Standard: 

Range: -5 to 1200 °C

Accuracy: -2 °C

Resolution: 0.1 ° C

Barometric Pressure (Standard): 

Range: 850-1150 mbar

Resolution: 0.1 mbar

Accuracy: 1 to 9.99

Resolution: 0.01

Flow Gas measurement (option) : 

Range: 3 to 100 m/sec

Accuracy: ± 1 m/sec or ± 3% of reading

Resolution: 0.1 m/sec

Digital & Software : 

Communications: mini USB, IRDA and Bluetooth as standard

Data logging: 16000 Data log on internal memory  & SD card

Mobile APP ( Free): MRU4U working on IOS & Android

Software (Optional): WIN4U emissions software

General: 

Pump  Rate ( internal): 60 l/hr

Included accessories: Water trap with filter, sampling hose, LI-ION rechargeable batteries, USB charger, charger lead and wall charger, soft caarrying case with space for analyser and accessories

Display: 3.5″ TFT colour display, 6 lines , graphic

Weight: 750 g

Dimension: 110x225x52

IP protection: IP 21

Power/main: LI-ION  AC 100-250 VAC, USB charger/lead supplied

Operating/Storage temperature: 5 to 45 °C/ -20 to 50 °C