Transducer Probe type: Single Element
Measurement & Thickness range
+ Interface Echo (IE): 1.65 - 25.40mm
+ Echo Echo (EE): 0.15 - 10.15mm
+ Plastic Mode (PLAS): 0.15 - 5.00mm
Measurement Accuracy: ±1% or 0.015mm (0.001”) - whichever is the greater
Resolution: 0.1mm (0.01”) or 0.01mm switchable
Measurement Rate: 4, 8 & 16Hz (4, 8 & 16 readings per second)
Operating Temperature: -10 to 50°C
Data Output: USB & Bluetooth
Power Supply: 2 x AA batteries
Battery Life 2 Alkaline: Approx. 15 hours Lithium: Approx. 28 hours
Gauge Weight : 210g - including batteries, without transducer
Gauge Dimensions: 145 x 73 x 37mm - without transducer
Packing List: Elcometer 307 Ultrasonic Precision Thickness Gauge, ultrasonic couplant, carry pouch,
3 x screen protectors, wrist harness, 2 x AA batteries, user guide, plastic transit case,
calibration certificate, ElcoMaster software CD & USB cable
Transducer not included