For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0

Experience ultra-fast data processing with the Keysight DAQ970A.

2026년 03월 04일 14시 46분 21초

The device incorporates a 6.5-digit multimeter, with a basic DC voltage accuracy of 0.003 percent per year. In full configuration, the system supports up to 120 channels and a scan rate of up to 450 channels per second when using solid-state switching modules.

When multiple measurement channels need to be recorded within the same system, requiring high accuracy and fast processing capabilities, the KEYSIGHT DAQ970A data processing unit is a suitable choice for R&D departments, component testing, and production lines.

Designed with 3 slots, easily expandable to suit different measurement needs

The DAQ970A has a main frame with 3 module slots, supporting a total of 9 types of switching and control modules. Users can configure it to measure temperature, voltage, current, resistance, or perform multi-point tests.

The device integrates LAN and USB ports, allowing control from a PC or access via an internal web browser. The 4.3-inch color screen displays measurements, trend graphs, bar graphs, and histograms directly on the device.

-Measures 14 types of signals in a single system

-Supports the following measurements:

-Temperature with thermocouple, RTD, and thermistor

-DC and AC voltage

-DC and AC current

-2-wire and 4-wire resistance

-Frequency and duty cycle

-Capacitance

-Diode testing

-Distortion

-6.5-digit resolution, equivalent to 22 bits, is suitable for high-precision measurements in laboratories and internal calibration.

See more at: Electrical data logger we distribute

Scans 450 channels per second at high speed, securely storing data

The maximum scanning speed reaches 450 channels per second. With the 4-channel DAQM909A module, the sampling rate reaches up to 800 kSa per second at 24-bit resolution, suitable for dynamic signal measurements or waveform analysis.

Internal memory stores up to 1 million measurements. The device retains up to 100,000 results even after power loss. Users can export data directly to a USB flash drive for storage or transfer configuration to another system.

Set up separate alerts for each measurement channel

Each channel can have its own independent high and low limits. When the value exceeds the threshold, the system activates a TTL alarm output to connect to an external alarm system or automated production line.

The scaling factor allows for unit conversion such as PSI or RPM directly on each channel, convenient for monitoring pressure, rotational speed, or other industrial parameters.

Suitable for R&D, component testing, and production monitoring

The DAQ970A is used in:

- Multi-point temperature data logging in environmental test chambers

- Batch testing of electronic components

- Voltage and current monitoring in production lines

With high accuracy, flexible scalability, and fast processing speed, the DAQ970A is well-suited for multi-channel measurements in professional engineering environments. It is a suitable choice when a stable data acquisition system is needed and easily integrated into existing infrastructure.

관련 뉴스

How do HRC, HRB, and HRA scales differ in hardness testing?
2026년 06월 15일 14시 30분 32초

HRC, HRB, and HRA all belong to the Rockwell hardness system but are applied to different material groups. Understanding the differences between HRC, HRB, and HRA helps in selecting the correct testing method, accurately reading specifications, and avoiding unnecessary errors in material quality assessment.

Common Errors in Fiber Loss Optic
2026년 06월 13일 09시 24분 06초

Optical power meter used together optical light source, can be applied to determine optical fiber link attenuation — a parameter that reflects the overall quality of the fiber optic cabling system

혜택 소식 받아보기

대량 할인, 도매 가격 업데이트 및 신제품 소식을 이메일로 받아보세요.

구독하면 당사의 서비스 이용약관개인정보 처리방침에 동의하는 것으로 간주됩니다.

빠른 지원

인증된 전문가에게 직접 연결