For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0

Experience ultra-fast data processing with the Keysight DAQ970A.

2026년 03월 04일 14시 46분 21초

The device incorporates a 6.5-digit multimeter, with a basic DC voltage accuracy of 0.003 percent per year. In full configuration, the system supports up to 120 channels and a scan rate of up to 450 channels per second when using solid-state switching modules.

When multiple measurement channels need to be recorded within the same system, requiring high accuracy and fast processing capabilities, the KEYSIGHT DAQ970A data processing unit is a suitable choice for R&D departments, component testing, and production lines.

Designed with 3 slots, easily expandable to suit different measurement needs

The DAQ970A has a main frame with 3 module slots, supporting a total of 9 types of switching and control modules. Users can configure it to measure temperature, voltage, current, resistance, or perform multi-point tests.

The device integrates LAN and USB ports, allowing control from a PC or access via an internal web browser. The 4.3-inch color screen displays measurements, trend graphs, bar graphs, and histograms directly on the device.

-Measures 14 types of signals in a single system

-Supports the following measurements:

-Temperature with thermocouple, RTD, and thermistor

-DC and AC voltage

-DC and AC current

-2-wire and 4-wire resistance

-Frequency and duty cycle

-Capacitance

-Diode testing

-Distortion

-6.5-digit resolution, equivalent to 22 bits, is suitable for high-precision measurements in laboratories and internal calibration.

See more at: Electrical data logger we distribute

Scans 450 channels per second at high speed, securely storing data

The maximum scanning speed reaches 450 channels per second. With the 4-channel DAQM909A module, the sampling rate reaches up to 800 kSa per second at 24-bit resolution, suitable for dynamic signal measurements or waveform analysis.

Internal memory stores up to 1 million measurements. The device retains up to 100,000 results even after power loss. Users can export data directly to a USB flash drive for storage or transfer configuration to another system.

Set up separate alerts for each measurement channel

Each channel can have its own independent high and low limits. When the value exceeds the threshold, the system activates a TTL alarm output to connect to an external alarm system or automated production line.

The scaling factor allows for unit conversion such as PSI or RPM directly on each channel, convenient for monitoring pressure, rotational speed, or other industrial parameters.

Suitable for R&D, component testing, and production monitoring

The DAQ970A is used in:

- Multi-point temperature data logging in environmental test chambers

- Batch testing of electronic components

- Voltage and current monitoring in production lines

With high accuracy, flexible scalability, and fast processing speed, the DAQ970A is well-suited for multi-channel measurements in professional engineering environments. It is a suitable choice when a stable data acquisition system is needed and easily integrated into existing infrastructure.

관련 뉴스

5 Little-Known Outdoor Error Sources of Laser Distance Meters
2026년 10월 10일 11시 23분 17초

Laser distance meters typically achieve millimeter-level accuracy indoors, but errors immediately appear when used on a blazing construction site. The root of the issue lies deep within the physical and optical mechanisms operating inside the device

How High CO2 Levels in Enclosed Classrooms Affect Students, and Where to Correctly Place Sensors for Measurement
2026년 10월 10일 10시 36분 22초

In classrooms where dozens of students sit in close proximity, air conditioners are turned on and windows kept tightly shut during hot weather, causing CO2 from exhaled breath to accumulate rapidly. This article addresses the questions frequently raised by school administrators, teachers, parents, and school management bodies covering everything from the impact on students and the CO2 thresholds requiring monitoring to the proper selection and installation of sensors

How a Lack of Fresh Air in Offices Causes Harm, Which Metrics Measure It, and What Solutions Address It
2026년 10월 09일 15시 43분 24초

Modern office buildings are designed to be airtight to retain cool air and conserve energy for central air conditioning systems. If the supply of fresh air falls below design specifications, CO2, fine dust, and volatile organic compounds (VOCs) begin to accumulate within the workspace. This impacts employee health, work quality, personnel costs, and the building owner's reputation. This article addresses the questions frequently raised by business owners, building managers, and HVAC engineers

Advantages of Lead-Free Soldering Stations
2026년 10월 09일 14시 45분 40초

Lead-free soldering stations provide fast, stable heating to meet stringent quality and durability requirements across industries such as aerospace, medical devices, and automotive electronics. They also help protect operators' health and reduce environmental pollution.

혜택 소식 받아보기

대량 할인, 도매 가격 업데이트 및 신제품 소식을 이메일로 받아보세요.

구독하면 당사의 서비스 이용약관 및 개인정보 처리방침에 동의하는 것으로 간주됩니다.

빠른 지원

인증된 전문가에게 직접 연결