For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

Fluke (Biomedical) PS320 Fetal Simulator

문의하기
안전한 결제
품질 보장
간편 교환 및 반품
배송 가능

Fetal ECG

Static rates: 0 BPM, 60 BPM, 90 BPM, 120 BPM, 150 BPM, 180 BPM, 210 BPM, and 240 BPM.

ECG sensitivity: 50 μV, 100 μV, 200 μV, 0.5 mV, 1 mV, and 2 mV.

US-1: Tracks primary fetal ECG rates.

US-2: Tracks secondary fetal activity for either independent “normal” or “twins” simulation; US-2 rate is fixed at 140 BPM.

Fetal patterns

Note: US-1 and fetal ECG track these selections. US-2 is in normal pattern, except during TREND #1 selection.

Trend #1: Twin fetal patterns

Normal: Normal pattern

Tachycardia: Tachycardia pattern

Bradycardia: Bradycardia pattern

Arrhythmias: Arrhythmia pattern

Late deceleration: Late deceleration

Early deceleration: Early deceleration

Moderate deceleration: Moderate variable deceleration

Acceleration #1: Acceleration wave #1

Acceleration #2: Acceleration wave #2

Sinusoidal (high): Sinusoidal pattern, large change

Sinusoidal (low): Sinusoidal pattern, small change

Severe variable deceleration #1: Severe deceleration wave #2

Severe variable deceleration #2: Severe variable deceleration

Prolonged deceleration: Prolonged deceleration

Biphasic deceleration: Biphasic deceleration

Exaggerated deceleration: Exaggerated deceleration

Non-uniform deceleration: Non-uniform deceleration

Variable deceleration (u): Variable deceleration, “U” shaped

Variable deceleration tach: Variable deceleration with high-rate BPM

Variable deceleration (v): Variable deceleration, “V” shaped

Variable deceleration (post): Variable deceleration, post exaggerated

Variable deceleration: Variable deceleration

Deceleration (position): Variable deceleration with position changes

Long deceleration: Long deceleration

Compensatory acceleration: Compensatory acceleration

Variability selections (added to fetal ECG)

Absent variability

Low variability

Mild variability

High variability

Severe variability

Long-term variability

Note: These patterns repeat and the TOCO channel will perform the selected TOCO waveform.

Maternal ECG

ECG static rates: 60 BPM, 80 BPM, 100 BPM, 120 BPM, 140 BPM, and 160 BPM.

ECG sensitivity: 0.5 mV, 1 mV, and 2 mV.

Pattern: Pattern selected during Trend #1 selection.

Uterine activity

Note: TOCO waveform selection is not available during Trend #1.

Execute waveform: Start TOCO waveform.

Uterine wave off: Stop TOCO waveform.

Analog: 0 V to 1 V; analog range 0 V to 1 V (1 V = 100 mmHg).

Uterine wave 0 to 25: Range of TOCO waveform.

Uterine wave 0 to 50: Range of TOCO waveform.

Uterine wave 0 to 100: Range of TOCO waveform.

Short duration: TOCO waveform of short duration.

Normal duration: Normal duration of TOCO waveform.

Increased duration: Long duration of TOCO waveform.

Uterine level = zero: Zero TOCO channel (automatic on power-up).

Uterine static +20: Increase TOCO static level by 20 mmHg (0–100 mmHg).

Increase resting tone: Resting tone increases.

Coupling: 2 close TOCO waves.

Tripling: 3 close TOCO waves.

Uterine pressure sensitivity: 5 μV or 40 μV on power-up.