For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

FLUKE 106 Digital Multimeter

재고 있음: 2
Model106
원산지China
보증1 년
문의하기
안전한 결제
품질 보장
간편 교환 및 반품
배송 가능

ACV: 6.000 V, 60.00 V, 600.0 V /1.0%

DCV: 6.000 V, 60.00 V, 600.0 V /0.5%

AC mV: 600.0 mV /3.0 %

Diode Test: yes

R: 400.0 Ω, 4.000 kΩ, 40.00 kΩ, 400.0 kΩ, 4.000 MΩ,40.00 MΩ /0.5%

C: 50.00 nF, 500.0 nF, 5.000 μF, 50.00 μF, 500.0 μF, 1000 μF

F: 50.00 Hz, 500.0 Hz, 5.000 kHz, 50.00 kHz,100.0 kHz

ACA: 4.000 A, 10.00 A /1.5 %

DCA: 4.000 A, 10.00 A /1.5 %

Battery : 2 AAA

Size (HxWxL: 142 mm x 69 mm x 28mm

Weight: 200 g

Manufacturer: Fluke

Made in China

Accuracy Specifications
FunctionRangeResolutionAccuracy
AC Volts16.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
1.0 % + 3
DC Volts6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
0.5 % + 3
AC Millivolts600.0 mV0.1 mV3.0 % + 3
Diode Test22.000 V0.001 V10 %
Resistance
(Ohms)
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5% + 3
Capacitance350.00 nF
500.0 nF
5.000 μF
50.00 μF
500.0 μF
1000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
Frequency4 Hz
(10 Hz – 100 kHz)
50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
NA
Duty Cycle41 % to 99 %0.1 %NA
AC Current
(40 Hz to 200 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
DC Current4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
  1. All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
  2. Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 ma="" li="">
  3. Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range).
  4. All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
FunctionOverload ProtectionInput Impedance (Nominal)Common Mode Rejection RatioNormal Mode Rejection Ratio
AC Volts600 V 1>10 MΩ <100 pf="" sup="">2>60 dB at dc,
50 Hz or 60 Hz
AC Millivolts600 mV>1M, <100 pf="" td="">>80 dB at 50 Hz or 60 Hz
DC Volts600 V 1>10 MΩ <100 pf="" td="">>100 dB at dc,
50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
  1. 6 x 105 V Hz Max
  2. For mV (AC), input impedance is approximately 1 MΩ.
General Specifications
Maximum Voltage Between any Terminal and Earth Ground600 V
Display (LCD) 6000 counts, updates 3/sec
Battery Type2 AAA, NEDA 24A, IEC LR03
Battery Life200 hours minimum
Temperature
Operating0 °C to 40 °C
Storage-30 °C to 60 °C
Relative Humidity
Operating HumidityNon-condensing when <10°C
≤90 % at 10 °C to 30 °C; ≤75 % at 30 °C to 40 °C
Operating Humidity, 40 MΩ Range ≤80 % at 10 °C to 30 °C; ≤70 % at 30 °C to 40 °C
Altitude
Operating2000 m
Storage12,000 m
Temperature Coefficient0.1 X (specified accuracy) /°C (<18 c="" or="">28 °C)
Fuse Protection for Current Inputs11A, 1000V Fast Fuse, Fluke specified part only
Size (HxWxL) 142 mm x 69 mm x 28mm
Weight 200 g
IP RatingIEC 60529: IP 40
SafetyIEC 61010-1: 600 V CAT III, Pollution Degree 2
Electromagnetic EnvironmentIEC 61326-1: Portable
Electromagnetic Compatibility Applies to use the Korea only. Class A Equipment (Industrial Broadcasting and Communication Equipment)1
  1. This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in homes.
혜택 소식 받아보기

대량 할인, 도매 가격 업데이트 및 신제품 소식을 이메일로 받아보세요.

구독하면 당사의 서비스 이용약관개인정보 처리방침에 동의하는 것으로 간주됩니다.

빠른 지원

인증된 전문가에게 직접 연결