For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

FLUKE 317 Clamp Meters (AC/DC 600A)

재고 있음: 1
Model317
원산지China
보증12개월
문의하기
안전한 결제
품질 보장
간편 교환 및 반품
배송 가능

ACA: 40.00 A, 600.0 A /1.5% ± 5 digit

ACA: 40.00 A, 600.0 A /1.5% ± 5 digit)

ACV: 600.0 V /1.5% ± 5 digit

DCV: 600.0 V /1% ± 4 digit

R: 400.0 Ω, 4000 Ω /1% ± 5 digit

Continuity:≤ 30 Ω

Digital Display:6000 count resolution

Power Source: Three AAA IEC LR03 batteries

Clamp Opening Size:1. 45 in (37 mm)

Dimensions (L x W x H): 162.4 mm x 58.25 mm x 30.5 mm

Weight: 384 g

Include:Test Leads, Soft Carrying Case, Three AAA batteries (Installed),User Manual

General Specifications
Digital Display
   6000 count resolution
Low Battery Indication
   Displays a signal when the batteries are below their required voltage
Power Source
   Three AAA IEC LR03 batteries
Clamp Opening Size
   1.45 in (37 mm)
Jaw Diameter
   1.45 in (37 mm)
Dimensions (L x W x H)
   6.39 in x 2.29 in x 1.20 in
   (162.4 mm x 58.25 mm x 30.5 mm)
Weight
   approximately 13.5 oz (384 g) (batteries included)
Auto Range
   Available in Ohms
Safety
   CE
   EN/IEC 61010-1 and IEC 61010-2-032
   Measurement Category: 600V CAT III
317 Electrical Specifications
Current AC
Range  40.00 A, 600.0 A
Resolution  0.01 A, 0.1 A
Accuracy  1.6% ± 6 digit (50-60 Hz) {40 A}
   2.5% ± 8 digit (60-500 Hz) {40 A}
   1.5% ± 5 digit (50-60 Hz) {600 A}
   2.5% ± 5 digit (60-500 Hz) {600 A}
Crest Factor add 2% into spec for CF > 2  3.0 Max @ 500 A, 2.5 Max @ 600 A
AC response  rms
Current DC
Range  40.00 A, 600.0 A
Resolution  0.01 A, 0.1 A
Accuracy  1.6% ± 6 digit (40 A)
   1.5% ± 5 digit (600 A)
Voltage AC
Range  600.0 V
Resolution  0.1 V
Accuracy  1.5% ± 5 digit (20-500Hz)
AC response  rms
Voltage DC
Range  600.0 V
Resolution  0.1 V
Accuracy  1% ± 4 digit
Resistance
Range  400.0 Ω, 4000 Ω
Resolution  0.1 Ω, 1 Ω
Accuracy  1% ± 5 digit
Continuity
   ≤ 30 Ω
Inrush
Integration time  N/A
Frequency
Range  N/A
Accuracy  N/A
Trigger Level  N/A
319 Electrical Specifications
Current AC
Range  40.00 A, 600.0 A, 1000 A
Resolution  0.01 A, 0.1 A, 1 A
Accuracy  1.6% ± 6 digit (50-60 Hz) {40 A}
   2.5% ± 8 digit (60-500 Hz) {40 A}
   1.5% ± 5 digit (50-60 Hz) {600/1000 A}
   2.5% ± 5 digit (60-500 Hz) {600/1000 A}
Crest Factor add 2% into spec for CF > 2  3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A
AC response  rms
Current DC
Range  40.00 A, 600.0 A, 1000 A
Resolution  0.01 A, 0.1 A, 1 A
Accuracy  1.6% ± 6 digit (40 A)
   1.5% ± 5 digit (600/1000 A)
Voltage AC
Range  600.0 V
Resolution  0.1 V
Accuracy  1.5% ± 5 digit (20-500Hz)
AC response  rms
Voltage DC
Range  600.0 V
Resolution  0.1 V
Accuracy  1% ± 4 digit
Resistance
Range  400.0 Ω
   4000 Ω
Resolution  0.1 Ω
   1 Ω
Accuracy  1% ± 5 digit
Continuity
   ≤ 30 Ω
Inrush
Integration time  100 ms
Frequency
Range  5.0 - 500.0 Hz
Accuracy  0.5% ± 5 digit
Trigger Level  10 - 100 Hz ≥ 5 A, 5 - 10 Hz, 100 - 500 Hz ≥ 10 A

Datasheet Fluke 317 »

혜택 소식 받아보기

대량 할인, 도매 가격 업데이트 및 신제품 소식을 이메일로 받아보세요.

구독하면 당사의 서비스 이용약관개인정보 처리방침에 동의하는 것으로 간주됩니다.

빠른 지원

인증된 전문가에게 직접 연결