For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

FLUKE 319 AC/DC 클램프 미터 (1000 A)

Model319
원산지China
문의하기
안전한 결제
품질 보장
간편 교환 및 반품
배송 가능

ACA: 40.00 A /1.6%, 600.0 A, 1000 A /1.5%

DCA: 40.00 A /1.6%, 600.0 A, 1000 A /1.5%

ACV: 0.1V ~ 600.0 V /1.5%

DCV: 0.1V ~ 600.0 V /1%

R: 400.0 Ω, 4000 Ω /%

Continuity: ≤ 30 Ω

F: 5.0 - 500.0 Hz /0.5%

Jaw Diameter: 1.45 in (37 mm)

Dimensions: (162.4 mm x 58.25 mm x 30.5 mm)

Weight:384 g

Includes: Test Leads, Soft Carrying Case, Three AAA batteries (Installed), User Manual

Manufacturer: Fluke

Made in China

General Specifications
Digital Display
   6000 count resolution
Low Battery Indication
   Displays a signal when the batteries are below their required voltage
Power Source
   Three AAA IEC LR03 batteries
Clamp Opening Size
   1.45 in (37 mm)
Jaw Diameter
   1.45 in (37 mm)
Dimensions (L x W x H)
   6.39 in x 2.29 in x 1.20 in
   (162.4 mm x 58.25 mm x 30.5 mm)
Weight
   approximately 13.5 oz (384 g) (batteries included)
Auto Range
   Available in Ohms
Safety
   CE
   EN/IEC 61010-1 and IEC 61010-2-032
   Measurement Category: 600V CAT III
317 Electrical Specifications
Current AC
Range  40.00 A, 600.0 A
Resolution  0.01 A, 0.1 A
Accuracy  1.6% ± 6 digit (50-60 Hz) {40 A}
   2.5% ± 8 digit (60-500 Hz) {40 A}
   1.5% ± 5 digit (50-60 Hz) {600 A}
   2.5% ± 5 digit (60-500 Hz) {600 A}
Crest Factor add 2% into spec for CF > 2  3.0 Max @ 500 A, 2.5 Max @ 600 A
AC response  rms
Current DC
Range  40.00 A, 600.0 A
Resolution  0.01 A, 0.1 A
Accuracy  1.6% ± 6 digit (40 A)
   1.5% ± 5 digit (600 A)
Voltage AC
Range  600.0 V
Resolution  0.1 V
Accuracy  1.5% ± 5 digit (20-500Hz)
AC response  rms
Voltage DC
Range  600.0 V
Resolution  0.1 V
Accuracy  1% ± 4 digit
Resistance
Range  400.0 Ω, 4000 Ω
Resolution  0.1 Ω, 1 Ω
Accuracy  1% ± 5 digit
Continuity
   ≤ 30 Ω
Inrush
Integration time  N/A
Frequency
Range  N/A
Accuracy  N/A
Trigger Level  N/A
319 Electrical Specifications
Current AC
Range  40.00 A, 600.0 A, 1000 A
Resolution  0.01 A, 0.1 A, 1 A
Accuracy  1.6% ± 6 digit (50-60 Hz) {40 A}
   2.5% ± 8 digit (60-500 Hz) {40 A}
   1.5% ± 5 digit (50-60 Hz) {600/1000 A}
   2.5% ± 5 digit (60-500 Hz) {600/1000 A}
Crest Factor add 2% into spec for CF > 2  3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A
AC response  rms
Current DC
Range  40.00 A, 600.0 A, 1000 A
Resolution  0.01 A, 0.1 A, 1 A
Accuracy  1.6% ± 6 digit (40 A)
   1.5% ± 5 digit (600/1000 A)
Voltage AC
Range  600.0 V
Resolution  0.1 V
Accuracy  1.5% ± 5 digit (20-500Hz)
AC response  rms
Voltage DC
Range  600.0 V
Resolution  0.1 V
Accuracy  1% ± 4 digit
Resistance
Range  400.0 Ω
   4000 Ω
Resolution  0.1 Ω
   1 Ω
Accuracy  1% ± 5 digit
Continuity
   ≤ 30 Ω
Inrush
Integration time  100 ms
Frequency
Range  5.0 - 500.0 Hz
Accuracy  0.5% ± 5 digit
Trigger Level  10 - 100 Hz ≥ 5 A, 5 - 10 Hz, 100 - 500 Hz ≥ 10 A

The accuracy specifications aply at 73 °F ± 41 °F (23 °C ± 5 °C)

Below 64 °F and above 82 °F (18 °C and above 28 °C) accuracy degrades at (0.1) times specification per °C.

True rms for ac V and ac A accuracy is specified from 5% to 100% of range.

Environmental Specifications
Operating Temperature
   14°F to 122°F (-10 °C to 50 °C)
Storage Temperature
   -40 °F to 140 °F (-40 °C to 60 °C)
Operating Humidity
   Non condensing (< 50 °F) (< 10 °C)
   90 % RH (50 °F to 86 °F) (10 °C to 30 °C)
   75 % RH (86 °F to 104 °F) (30 °C to 40 °C)
   45 % RH (104 °F to 122 °F) (40 °C to 50 °C)
   (Without Condensation)
Operating Altitude
   1 mile (2000 meters) above mean sea level
Storage Altitude
   7 miles (12,000 meters) above mean sea level
IP Rating
   IP40
Vibration Requirements
   Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis
Drop Test Requirements
   3 ft (1 m) drop test, six sides, oak floor
EMI, RFI, EMC
   Instrument unspecified for use in EMC field ≥ 0.1 V/m
Temperature Coefficients
   0.1x (specified accuracy)/ °C
   (<64 f="" or=""> 82° F)
   (<18 c="" or=""> 28 °C)

Datasheet Fluke 319 »