DCV: 0 – 600.0 V /1% ± 5 counts

ACV (True RMS): 0 – 600.0 V /1% ± 5 counts

ACA(True RMS): 0 – 600.0 A /2.0% ± 5 counts

DCA: 0 - 200.0 µA /1.0% ± 5 counts

R: 0 – 9999 Ω /1.5% ± 5 counts

Continuity: yes           

Temperature type K: -10 oC to 400 oC (-14 oF to 752 oF)

C: 1-1000 µF /1.9% ± 2 counts

Weight: 1.5 lbs (.7 kg)

Dimensions: 10.75” x 4.25” x 2.44” (27.3 cm x 10.8 cm x 6.2 cm)

Battery type: 2xAA Alkaline Batteries

Includes: 2xAA Alkaline batteries, Users manual, Soft carrying case, TL75 Test Leads , 80BK Integrated DMM Temperature Probe

Specifications
Voltage DC
Range  0 – 600.0 V
Accuracy  1% ± 5 counts
Voltage AC (True RMS)
Range  0 – 600.0 V
Accuracy  1% ± 5 counts (50/60 Hz)
Current AC (True RMS)
Range  0 – 600.0 A
Accuracy  2.0% ± 5 counts (50/60 Hz)
Current DC
Range  0 - 200.0 µA
Accuracy  1.0% ± 5 counts
Resistance
Range  0 – 9999 Ω
Accuracy  1.5% ± 5 counts
Continuity
   <= 30 Ω
Temperature*
(Type K Thermocouple)
Range  -10 degree C to 400 degree C (-14 degree F to 752 degree F)
Accuracy  +/- 1.0% + 0.8 degree C (+/- 1.0% + 1.5 degree F) typical
Range  -40 degree C to -10 degree C (-40 degree F to -14 degree F)
Accuracy  +/- 5.0% + 1.5 degree C (+/- 5.0% + 3.3 degree F) typical
Capacitance
Range  1-1000 µF
Accuracy  1.9% ± 2 counts


* Error does not include Type K Thermocouple errors

Mechanical & General Specifications
Weight
   1.5 lbs (.7 kg)
Dimensions
   10.75” x 4.25” x 2.44” (27.3 cm x 10.8 cm x 6.2 cm)
Battery type
   (2) AA Alkaline Batteries

Datasheet »