인증된 전문가에게 직접 연결
인증된 전문가에게 직접 연결
Features
ISE accuracy: 0.5 % f. s. for monovalent ions - 1 % for divalent ions
Accuracy (pH): ±0,002
Accuracy (Salinity): ±1 % f.s.
Accuracy (Temperature): ±0,2
Magnetic stirrer: Yes, independently controlled
Temperature calibration: Yes
AQA calibration: Yes
Temperature coefficent (max): 0,00 ... 10,00
DHS compatibility: Yes
Temperature compensation: 0,0 ... +100,0
Ultrapure water compensation: Yes for values below 10 µS
PC Communication: USB type B
Printer connection: RS 232
Stirring speed control: 15 levels
Cell constant: 2 rings: 0.1 / 1 / 10 | 4 rings: 0.55
Criteria for stability of the measure: Med - High - Tit | Secondi (ISE)
Dimension: 324 x 185 x 56
TDS factor: 0,40 ... 1,00
Warranty: 3
AQA: Yes
Inputs: 2 x BNC - 2 x RCA - Multipin - 4 mm banana
Selectable languages: Eng - Ita - Deu - Esp - Fra - Por
Memory: 8000
Parameters: pH - mV - ORP - ISE - Cond - TDS - Sal - Res - T
Password: 6 to 10 characters with a capital letter, a number and a symbol
Weight: 1,255
Ion measuring range: 0,001 ... 19999
mV ORP measuring range: -2000 ... +2000
PH calibration points: 1 ... 5 automatic values - 1 ... 5 user values
pH measuring range: -2,000 ... +20,000
Resistivity measuring range: 1,00 Ω ... 10,00 MΩ
Salinity measuring range: 0,01 ppm … 100 ppt
Cond resolution: 0,01 / 0,1 / 1 (scala automatica)
ORP resolution: 0.1 / 1 (automatic)
pH resolution: 0,1 / 0,01 / 0,001
Temperature resolution: 0,1
Buzzer: Yes
Timer calibration due with alarm: Si
Cell type: 2 rings - 4 rings
ION measuring unit: mg/l - g/l - mol/l
Stirring speed: 0 ... 3000
Max stirring quantity: 2
Power supply: 100 - 240
Analog view: Yes
Supplied as standard: S7/BNC cable, NT 55 temperature probe, stand electrode holder, coloured buffer solutions, keyboard external keyboard, USB cable and multi-socket power supply unit.
Accuracy (TDS): ±1 % f.s.
pH alarm range: Min - Max
Recognised pH buffers: USA - NIST - DIN 19266 - Mettler Toledo Eu - Merck
Swabs recognised Cond: 84 µS - 147 µS - 1413 µS - 12,88 mS - 111,8 mS
Working temperature: 0 ... +45
Reference temperature: +15 ... +30
Accuracy (Cond): ±0,5 % f.s.
Display: 4.3" high-definition, backlit colour TFT
Calibration data indication: Yes with reports
Buffer used indication: Yes with icon
Electrode status indication: Yes with graph and icon
Calibration points Cond: 1 ... 4 automatic values - 1 user value
ION calibration points: 2 ... 5
ORP calibration points: 1 automatic value - 1 user value
Cond measuring range: 0,00 μS ... 1000 mS
TDS measuring range: 0,1 mg/l ... 500 g/l
temperature measurement range: -30,0 ... +130,0
Calibration Report: Yes, printable
Customised Print Reports: 4 customisable print templates
Access Profiles: 3 livelli per 15 utenti; livello Guest libero
ORP alarm thresholds: Min - Max
Simultaneous Display pH_Cond: Yes
Entering identifiers: Yes via external keyboard
Audit Trail: Yes via PC software
Multiview: Yes, up to 6 parameters simultaneously
Data storage modes: Manual - Automatic - Auto with Min/Max threshold - Auto with delta value
TDS unit of measurement: mg/l - g/l | ppm - ppt
Unit of measurement Salinity: ppm - ppt | mg/l - g/l