Gossen Metrawatt METRACLIP 61 Digital Leakage Current Clamp (30 ~ 300mA; 30 ~ 300A)
Alternating Current mA AC/A AC (Manually Selectable)
Measuring Range/ Range of Application/ Resolution/ Accuracy
0~30 mA, 0~300 mA/ 0~300 mA/ 0.01 mA, 0.1 mA/ ±1.2% rdg. ±5 digits
0~30.00 A, 0~300.0 A/ 0~200 A, 200~250 A, 250~300 A/ 0.01 A, 0.1 A/ ±1.2% rdg. ±5 digits, ±3% rdg. ±5 digits, ±5% rdg. ±5 digits
Frequency range: 50 ~60 Hz
Measuring principle: arithmetic mean
Reference Conditions
Ambient temperature: +23°C±5°C
Relative humidity: max. 80%
LCD Panel
Display: 7-segment characters and bargraph
Number of digits: 3½ digits, max. display: 3200
Sampling rate:
Digital display: 2 per second
Bargraph: 12 per second
Overflow display: OL appears
DATA HOLD display: DH appears
Power Supply
Batteries: 2 x LR44 or SR44
Mechanical Design
Protection: IP 40
Clamp opening: max. diameter 40 mm
Dimensions W x H x D: 64 mm x 176 mm x 23 mm
Weight approx. 125 g with batteries
인증된 전문가에게 직접 연결