Common Issues with Analog Multimeters

Before starting any repair, you need to identify the problem. The most common issues include:

  • The needle does not move even when the probes are connected to a power source

  • Measurement results show large deviations compared to actual values or another reference device

  • When shorting the probes, the needle does not return to zero on the Ohm scale

  • Internal circuit damage, often caused by selecting the wrong measurement range (e.g., measuring voltage while set to current mode)

Troubleshooting and Repair Guide

Check Battery and Fuse (Most Common Issue)

Up to 80% of analog multimeter failures are caused by a dead battery or a blown fuse.

How to fix:

Open the back cover and check the 9V or 1.5V battery

If there is leakage, clean the contact springs thoroughly

Check the fuse; if it is burnt or broken, replace it with the correct type (typically 0.5A/250V)

Fix a Stuck or Misaligned Needle

If the needle is stuck or does not rest at the correct position:

How to fix:

Use a small flat screwdriver to adjust the mechanical zero adjustment screw located near the needle axis on the front panel

Gently turn it until the needle aligns with the zero mark on the left side

If dust is causing the issue, use compressed air to carefully clean the internal coil area

Repair Burnt Internal Resistors (Wrong Range Selection)

If you accidentally set the meter to Ohm mode while measuring 220V mains, internal resistors may burn out.

How to fix:

Open the circuit board and identify resistors with burn marks

Use another multimeter to measure their values

Replace them with resistors of the exact same specifications

In cases of severe damage, it is better to replace the analog multimeter or consider switching to a digital one. This is often the most efficient solution in terms of time, cost, and reliability. You can easily check prices and choose popular models from trusted brands like Kyoritsu, Sanwa, or Fluke, Hioki.

Important Notes When Repairing at Home

  • After repair, the multimeter may lose its original accuracy. Calibration is recommended to ensure acceptable error levels

  • Do not attempt to fix issues related to the range selector if you lack expertise, as this can be dangerous when measuring high voltage

  • If the device is too old or the magnetic movement (needle core) is damaged, repairs are often ineffective. In such cases, consider upgrading to a newer generation multimeter for better performance and safety

If repairing the device is too complicated or you want to upgrade to a more durable model, visit EMIN. We offer a wide range of multimeters from budget to high-end options. 

관련 뉴스

What Is Fiber Polarity and How Do You Choose an MPO Method?
2026년 11월 14일 11시 35분 16초

Fiber polarity ensures the transmit path connects to the corresponding receive path. For MPO-based duplex channels, the selected method must remain consistent across trunks, cassettes, adapters, and patch cords.

The scent of new wood in a newly handed-over apartment: How to measure and address formaldehyde (HCHO) levels before moving in
2026년 11월 14일 10시 28분 19초

Many people refer to the pungent, acrid odor that emerges when opening a new cabinet as the "smell of new wood," assuming it will simply dissipate after a few days. In reality, however, what is being released could well be formaldehyde—a substance originating from the adhesives used in the pressed-wood panels—and our sense of smell is not a reliable enough gauge to determine the concentration levels present

Guide to Selecting a TCLP Toxicity Characteristic Leaching Procedure Shaker Configuration in Compliance with QCVN 07:2025/BNNMT and TCVN 9239:2012
2026년 11월 13일 17시 23분 39초

Regulation QCVN 07:2025/BNNMT (replacing QCVN 07:2009/BTNMT and QCVN 50:2013/BTNMT) specifies hazardous waste and sludge thresholds based on leachate concentrations. To ensure that analytical results for heavy metals and organic compounds are accepted during ISO/IEC 17025 or VIMCERTS assessments, laboratories must comply with the Toxicity Characteristic Leaching Procedure (TCLP) specified in TCVN 9239:2012, which is equivalent to US EPA Method 1311

Checking the Temperature of Paint and Coating Surfaces After Curing Using an Infrared Thermometer
2026년 11월 13일 16시 11분 22초

An infrared thermometer allows surface temperature measurement without direct contact, making it suitable for products coming out of curing ovens or surfaces that are difficult to access. However, to ensure reliable results for production quality control, it is important to understand the measurement principle and the factors that affect measurements on painted and coated surfaces.

Crowded Gyms and Yoga Studios: How to Manage Air Quality to Retain Members
2026년 11월 13일 15시 07분 40초

Around 6 or 7 in the evening, the gym becomes packed; the music drowns out the sound of heavy breathing, and the air conditioning runs at full blast behind closed doors. At first glance, everything seems fine: the room is cool, the lights are bright, and the equipment is state-of-the-art. Yet, after just a few sessions, regular members begin to feel a heavy-headedness and find themselves running out of breath more quickly eventually, they simply stop renewing their memberships. No one complains about the personal trainers or the exercise machines. The very thing that makes them feel stifled and drives them away is something entirely invisible: the air inside the room

혜택 소식 받아보기

대량 할인, 도매 가격 업데이트 및 신제품 소식을 이메일로 받아보세요.

구독하면 당사의 서비스 이용약관 및 개인정보 처리방침에 동의하는 것으로 간주됩니다.

빠른 지원

인증된 전문가에게 직접 연결