Proper calibration of self-recording thermometers and hygrometers.

2026년 01월 06일 10시 46분 58초

A self-recording hygrometer is a device used to monitor the temperature and humidity of the air. The device can automatically record data over time, allowing users to easily understand changes in the surrounding environment. The information is displayed visually on the screen, making observation and management of spatial conditions easier and more convenient.

What is calibration for a data logging thermometer/hygrometer?

Simply put, calibration is the process of bringing a hygrometer back to a state that accurately measures real-world values. After prolonged use, the sensor is easily affected by the environment, high humidity, constantly changing temperatures, or component degradation. In such cases, the data may still be displayed, but the deviation may gradually increase, making it difficult for users to accurately assess air conditions.

Typically, this process is performed at testing or warranty centers, where standard equipment is available for comparison and adjustment. This method helps keep the error within acceptable limits and ensures the device maintains stable operation.

Users can perform the operation themselves if they have technical knowledge and the necessary tools. However, incorrect operation can easily misalign the sensor, even causing damage or risks during use. For equipment used in storage, laboratories, or for long-term monitoring, choosing a professional service provider is still a safer option.

Why is calibration necessary for data logging thermometers and hygrometers?

After a period of use, self-recording hygrometers are inevitably prone to measurement inaccuracies or minor sensor errors. Environmental changes, high humidity, constantly fluctuating temperatures, or simply component degradation can all cause measurement results to no longer accurately reflect reality. Continued use in this state will result in less valuable and less reliable data for monitoring purposes.

Typically, a calibration cycle is recommended around every six months. This timeframe allows for a comprehensive check of the device's functionality and adjustment of parameters to ensure more stable temperature and humidity measurements. This helps maintain the necessary accuracy over long-term use.

See also: Humidity-Temperature Data Logger

Calibration procedure for self-recording hygrometers

1. External Inspection

The first step is to observe the device as a whole. Compare the size, appearance, display screen, and power supply with the information on the manufacturer's label. This inspection helps to detect early display errors, power supply errors, or basic malfunctions that may affect subsequent measurement results.

2. Measuring and Calibrating Humidity

Common humidity levels for testing include 30% RH, 60% RH, and 90% RH, depending on actual usage requirements. Place the self-recording hygrometer and standard probe together in a humidity chamber. After the environment stabilizes, compare the data and determine the difference. If the error exceeds the permissible limit, the technician will readjust the equipment according to the agreed-upon requirements. A calibration certificate will be issued upon completion of this process.

3. Temperature Measurement and Calibration

The commonly selected temperature levels are 15°C, 25°C, and 35°C, or according to specific application conditions. The equipment to be calibrated and the reference probe are placed in the temperature-generating chamber. The chamber is adjusted sequentially to each mark, and then the measurement results are compared to identify any discrepancies. If necessary, the parameters are fine-tuned to bring the equipment to a stable measurement state.

4. Recommendations

Regular calibration is recommended to ensure the reliability of recorded data. In cases of significant errors or unstable operation, calibration may be performed earlier than scheduled.

Notes on calibrating a self-recording thermometer/hygrometer.

The ideal environment for this experiment is between 18 and 28 degrees Celsius, with humidity ranging from 20% to 80%. Before starting, it is necessary to prepare the heating and humidifying chamber, reference equipment, and humidification chamber to ensure a smooth process and accurate results.

관련 뉴스

Which Vacuum Pump Should You Choose for a Microbiology Lab to Avoid Affecting Samples?
2026년 07월 15일 14시 45분 07초

Vacuum pumps are utilized in a wide range of microbiology laboratory procedures, from membrane filtration and the aspiration of supernatants following centrifugation to sample concentration and the support of negative-pressure systems. Selecting the appropriate pump not only ensures more stable operational processes but also minimizes the risk of sample contamination, reduces maintenance costs, and extends the equipment's lifespan

QCVN 25:2025/BKHCN Takes Effect: Do Businesses Need to Prepare Electrical Safety Testing Equipment?
2026년 07월 15일 09시 15분 04초

Electrical safety is consistently one of the primary criteria evaluated before electrical or electronic equipment—or industrial components—are released to the market. A product may operate reliably yet still fail to meet requirements if its insulation lacks sufficient durability, its grounding resistance exceeds permissible limits, or leakage current occurs during operation.

Why Is Associated Research Considered an Icon of Hipot Technology?
2026년 07월 14일 09시 05분 30초

When it comes to electrical safety testing equipment specifically Hipot testers—many QA/QC and testing engineers are familiar with the globally renowned brand Associated Research. A subsidiary of the parent company IKONIX, Associated Research (ARI) invented the world's first commercial Hipot tester.

What Is the Standard 3-Phase Voltage? How to Read Cabinet-Mounted Meters Without Errors
2026년 07월 13일 15시 09분 18초

Voltmeters are almost invariably found on the panels of electrical cabinets in factories, power stations, or generator systems. A glance lasting just a few seconds allows an operator to determine whether the power supply is stable or showing signs of abnormality. However, not everyone understands the significance of the displayed readings, particularly regarding three-phase electrical systems.

Distinguishing between ARI’s Hypot, HypotUltra, and HypotMax: Which device is right for your factory?
2026년 07월 13일 09시 48분 30초

Few people realize that the concept of the "Hipot Test"—or electrical safety testing—has long existed within the electrical equipment manufacturing industry. Driven by the growing need to verify the voltage withstand capabilities of conductors, motors, and electrical devices, the industry required a robust and virtually fail-safe method to detect insulation weaknesses before products reached the market.

혜택 소식 받아보기

대량 할인, 도매 가격 업데이트 및 신제품 소식을 이메일로 받아보세요.

구독하면 당사의 서비스 이용약관개인정보 처리방침에 동의하는 것으로 간주됩니다.

빠른 지원

인증된 전문가에게 직접 연결