인증된 전문가에게 직접 연결
인증된 전문가에게 직접 연결
For performing fast voltage dips and drops (micro-interruptions) according to standard requirements, mainly from vehicle manufacturers.
Mainframe
Microprocessor controlled touch panel: 7”, capacitive
Ethernet Interface: Built-in, for remote control of the generator
Interface for saving reports: USB
External trigger input/output: no / 10 V
Connector for external safety interlock loop: 24 V=
External red and green warning lamps: acc. to VDE 0104, 24 V=, 40 mA
Mains power: 90 V - 264 V, 50/60 Hz
Dimensions (desk top case, W × H × D): 450 × 180 × 500 mm³
Weight: 15 kg
Automotive Power Fail Simulator
E.U.T. voltage (maximum): 70 V DC
E.U.T. current (maximum): 100 A
Short circuit protection: Amplifier limited
Fall- and rise switching time: <1 µs
Rated current / Inrush current (maximum): >100 A
Monitor output for mains voltage and mains current: Built-in
Initialization time: 0 - 1000 ms
Wait time: 1 – 1000 s
Duration: 10 µs – 10 s
ES module: 8 electronic switches, 2 A, 70 V, <10 µs switching time
Short circuit protection: 2 A - T Fuse