인증된 전문가에게 직접 연결
인증된 전문가에게 직접 연결

Mainframe
Microprocessor controlled touch panel: 7”, capacitive
Optical Ethernet Interface for remote control of the generator: optional
Interface for saving reports: USB
External trigger input / output: Switch/ 10 V
Connector for external safety interlock loop and external red and green warning lamps (acc. to VDE 0104): 24 V=, 40 mA
Mains power: 230 V, 50/60 Hz
Mains synchronous triggering, phase shifting, digitally selectable: 0 - 359°, step 1°
Pulse generator section
Max. stored energy: 14000 Ws
Peak value of charging voltage, adjustable: 0 - 20 kV, ± 2%
Charging time for max. charging voltage: < 117 sec
Waveform of impulse output current (30 – 100 kA): 8 / 20 µs ± 10 %
Impulse output current, adjustable via charging voltage: 2 - 100 kA ± 10 %
Output pulse polarity, switchable: POS/NEG
Pulse repetition rate for 100 kA: 1/117 sec
Pulse repetition rate for 40 kA (with Varistor Vv=1800V on HV output): < 1/60 sec
Current viewing resistor, built-in: 0.25 mΩ (1 mΩ), 10 MHz
Impulse current output terminals: M12 bolts in the test chamber
Test adapter on the output terminals: M12 bolts
Ground rod: In test chamber
Dimensions (19"-cabinet W * H * D): 560 * 1950 * 950 mm³
Weight: 265 kg