Accuracy: Cx: ±(reading×1%+1pF)

tgδ: ±(reading×1%+0.00040)

Anti-interference: Variable frequency anti-interference, the above accuracy can be reached under 200% interference. 

Capacitance range: Internal HV: 3pF~60000pF/10kV 60pF~1μF/0.5kV

External HV: 3pF~1.5μF/10kV 60pF~30μF/0.5kVResolution: Maximum 0.001pF, 4 valid figures.

tgδ range: unlimited, 0.001% resolution, automatic identification for capacitance, inductance and resistance of three tested articles. 

Test current range: 10μA~1A

Internal HV: Set voltage range: 0.5~10kV

Maximum output current: 200mA

Buck-bust method: continuous stepless regulation

Test frequency: 45, 50, 55 single frequency

45/55Hz automatic dual variable frequency

Frequency accuracy: ±0.01Hz

External HV: In case of UST, maximum test current is 1A, and power frequency or variable frequency is 40-70Hz

In case of GST, maximum test current is 10kV/1A, and power frequency or variable frequency is 40-70Hz

CVT self-exciting low voltage output: Output voltage 3~50V, output current 3~30A

Measuring duration: About 40s, depending on measuring method

Input power supply: 180V~270VAC, 50Hz/60Hz±1%, supplied by alternating current or generator

Printer: WH-A7 mini-type thermal printer

Environment temperature: -10℃~50℃

Relative humidity: <90%

Overall dimension:460×360×350mm

Weight:28kg