For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

HV HIPOT GDPT-103C Onsite Calibrator for CVT (0~100V)

ModelGDPT-103C
원산지China
보증1 년
문의하기
안전한 결제
품질 보장
간편 교환 및 반품
배송 가능

Test range of turns ratio:  

6kV / 100V, 6kV/√3/ 100V/√3

10kV / 100V, 10kV/√3/ 100V/√3

35kV / 100V, 35kV/√3/ 100V/√3

110kV /100V, 110kV/√3/100V/√3

220 / 100V,220kV/√3/100V/√3

Accuracy: 0.02%

Error measurement accuracy: 0.05%

Partial pressure ratio measurement accuracy: 0.5%

Partial capacitance measurement accuracy: 2%

DC resistance measurement accuracy: 0~0.1Ω 3%; 0.1~50Ω 1%

Working environment: temperature:5℃~40℃, humidity:<80%(25℃)

Altitude:<2500m, power frequency:50±0.5Hz

Verification part:

- voltage range: 0~100V (percentage error 0.5%)

- Ratio difference: 0.001%~3% (100V)

- Angle difference: 0.00'~50' (100V)

+Error: *X=±(2%×X+2%×Y±2 words)

                *Y=±(2%×X+2%×Y±2 words)

- Admittance: 0.1ms~99.9ms

  + Error: *X=±(2%×X+2%×Y±2 words)

                     *Y=±(2%×X+2%×Y±2 words)

Dimension: 496*394*185 mm

Weight: About 14kg