Specification
Probe: FM (included) magnetic induction probe
Range: 0-1500µm
Resolution: 0.1µm (<100µm)
1µm (100µm~10000µm)
Accuracy*:
Zero calibration: ±(1µm+2%L)
Multi-point calibration: ±(1µm+1%L)
Measuring mode: single point measurement, scan mode, differential mode, average mode
Calibration mode: zero calibration, one-point callbration, two-point calibration, multi-point calibration
Minimum substrate thickness: 0.5mm
Minimum measuring area: Ø7mm
Minimum curvature radius of convex workpiece: 1.5mm
Data storage: 500 groups
Interface: USB, Bluetooth
Operation temperature: -10°C~50°C
Power supply: 3x1.5V AAA batteries
Dimension: 150×70×30mm
Weight: 160g
Probe: FL (optional) mid-range magnetic induction probe
Range: 0-3000µm
Resolution: 0.1µm (<100µm)
1µm (100µm~10000µm)
Accuracy*:
Zero calibration: ±(1µm+3%L)
Multi-point calibration: ±(1µm+2%L)
Measuring mode: single point measurement, scan mode, differential mode, average mode
Calibration mode: zero calibration, one-point callbration, two-point calibration, multi-point calibration
Minimum substrate thickness: 0.5mm
Minimum measuring area: Ø7mm
Minimum curvature radius of convex workpiece: 1.5mm
Data storage: 500 groups
Interface: USB, Bluetooth
Operation temperature: -10°C~50°C
Power supply: 3x1.5V AAA batteries
Dimension: 150×70×30mm
Weight: 160g
Probe: FX (optional) high-range magnetic induction probe
Range: 0-10000µm
Resolution: 0.1µm (<100µm)
1µm (100µm~10000µm)
Accuracy*:
Zro calibration: ±(2µm+5%L)
Multi-point calibration: ±(1µm+3%L)
Measuring mode: single point measurement, scan mode, differential mode, average mode
Calibration mode: zero calibration, one-point callbration, two-point calibration, multi-point calibration
Minimum substrate thickness: 2mm
Minimum measuring area: Ø40mm
Minimum curvature radius of convex workpiece: 10mm
Data storage: 500 groups
Interface: USB, Bluetooth
Operation temperature: -10°C~50°C
Power supply: 3x1.5V AAA batteries
Dimension: 150×70×30mm
Weight: 160g
Probe: FS (optional) low-range magnetic induction probe
Range: 0-500µm
Resolution: 0.1µm (<100µm)
1µm (100µm~10000µm)
Accuracy*:
Zero calibration: ±(1µm+2%L)
Multi-point calibration: ±(1µm+1%L)
Measuring mode: single point measurement, scan mode, differential mode, average mode
Calibration mode: zero calibration, one-point callbration, two-point calibration, multi-point calibration
Minimum substrate thickness: 0.2mm
Minimum measuring area: Ø3mm
Minimum curvature radius of convex workpiece: 1mm
Data storage: 500 groups
Interface: USB, Bluetooth
Operation temperature: -10°C~50°C
Power supply: 3x1.5V AAA batteries
Dimension: 150×70×30mm
Weight: 160g
Probe: FH (optional) high-temp magnetic induction probe
Range: 0-3000µm
Resolution: 0.1µm (<100µm)
1µm (100µm~10000µm)
Accuracy*:
Zero calibration: ±(1µm+3%L)
Multi-point calibration: ±(1µm+2%L)
Measuring mode: single point measurement, scan mode, differential mode, average mode
Calibration mode: zero calibration, one-point callbration, two-point calibration, multi-point calibration
Minimum substrate thickness: 0.5mm
Minimum measuring area: Ø7mm
Minimum curvature radius of convex workpiece: 1.5mm
Data storage: 500 groups
Interface: USB, Bluetooth
Operation temperature: -10°C~50°C
Power supply: 3x1.5V AAA batteries
Dimension: 150×70×30mm
Weight: 160g
Probe: NM (optional) eddy current probe
Range: 0-1500µm
Resolution: 0.1µm (<100µm)
1µm (100µm~10000µm)
Accuracy*:
Zero calibration: ±(1µm+2%L)
Multi-point calibration: ±(1µm+1%L)
Measuring mode: single point measurement, scan mode, differential mode, average mode
Calibration mode: zero calibration, one-point callbration, two-point calibration, multi-point calibration
Minimum substrate thickness: 0.3mm
Minimum measuring area: Ø5mm
Minimum curvature radius of convex workpiece: 3mm
Data storage: 500 groups
Interface: USB, Bluetooth
Operation temperature: -10°C~50°C
Power supply: 3x1.5V AAA batteries
Dimension: 150×70×30mm
Weight: 160g
*L is the measured value in µm.
Standard delivery
Main unit: 1 pc
Magnetic induction probe (FM): 1 pc
Zero calibration block for FM probe: 1 pc
Calibration foils(12/50/100/250/500/1000μm): 6 pcs
AAA battery: 3 pcs
Software and USB cable: 1pc
- Magnetic induction probe (FM) measures the thickness of non-magnetic coating and non-metallic coating on magnetic metal substrate.
Substrate: steel, iron, alloy, hard magnetic steel, etc.
Coating: zinc, aluminum, chrome, copper, rubber, paint, etc.
- Eddy current probe (NM) measures the thickness of non-conductive coating on non-magnetic metal substrate.
Substrate: copper, aluminum, zinc, tin, etc.
Coating: rubber, paint, plastic, anodized film, etc.
- Real-time temperature compensation guarantees high accuracy, thin plating and
oxide layer less than 20μm can be measured accurately
- Reduces the effects of electromagnetic interference and hand-held operation
- Probe can be re-matched after abrasion
- Tolerance measurement with adjustable alarm threshold
- USB and bluetooth interface for data transmission and online measurement in real-time
- Coupling status indication
- Support cable printer
Datasheet