1. Measuring VMOS Tube can display simultaneously:
On-state resistance Ron: 1~999mΩ (when more than 999mΩ, automatically turns to 9.99Ω)
Transconductance Gfs: 0~99.9S
Opening voltage Ut: 1~7.5V
Interelectrode capacitance Cir: 0.1~9.9 (NP)
2. Through auxiliary function keys, you can also get:
a. Cir: 1% nP accuracy
b. Ut: 1%V accuracy
c. When measuring Ron: Ids (max A), Vds (min V)
d. When measuring Ggs: Ids (A), Vds (V), Vgs (V)
3. 10-bit LED display.
4. Uses industrial switching power supply, operates in: 160V~230V.
Transconductance Gfs Ron: 0999mΩ, accurate to 1mΩ (when more than 999mΩ, automatically turns to 9.99Ω)
Transconductance Gfs: 099.9S, accurate to 10% S
Turn-on Voltage Ut: 08.0V, accurate to 10% V
Interelectrode Capacitance Cir: 09.9 (NP), accurate to 10% NP
Datasheet
Product notes: VMOS tube can be measured at the same time: on state resistance Ron 1~999m, transconductance Gfs 0~99.9S
Product category: MOS tube tester
Changzhou JK9612 field effect tube sorting tester, The JK9612 field effect tube sorting instrument quotation is mainly used in the batch measurement and screening of the field effect transistor or IGBT in the small and medium-sized electronic products enterprises.
1. The use of high-precision AD, To meet the measurement accuracy, High speed microprocessor and electronic switch, Make the measurement work fast, efficient and quiet,Use International advanced pulse measurement , can provide 10A~max 75A test current , Will not make the measured tube heating. Automatic current sharing function to ensure the safety of the tested pipe.
2. It has the function of self checking, measuring and judging and fault alarm indication , When not Vmos tube or wrong insertion , Measurement cannot continue. Before and after measurement,Measure the short circuit between the source of the outlet .In order to ensure the measuring tube was inserted into or pulled out of the safety socket
3. 20A~150A capacity selection, Even if the wrong current file, Measurement of small capacity pipe with maximum current, Will not damage the measured tube.
4. You can set the parameter range as required. Can be set:Open voltage Ut, transconductance Gfs, on state resistance Ron and Lower and upper limits of the interelectrode capacitance Cir .For transfinite measurement ,Buzzer alarm, And which parameters overrun, flashing prompt,Users can not meet the standards of the specific parameters of the data, only in the alarm when the attention of the flashing parameters, This greatly facilitates the industrial batch measurement.
5. The use of simple, do not need professional knowledge.