For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

Junray ZR-1211 마스크 호흡 저항 테스터 (160L/min, ±1L/min)

문의하기
안전한 결제
품질 보장
간편 교환 및 반품
배송 가능

Short Description:

ZR-1211 mask resistance tester is used to test inhalation and exhalation resistance of masks in regulated test condition. Compatible  to multiple flow rates, is suitable to perform related inspection and test of masks for mask manufacturers, national inspection institutes of labor protection devices.

Specification

Test flow: 

Parameter range: 160L/min, Resolution: 0.1L/min, Maximum permitted error: ±1L/min

Parameter range: 95L/min, Resolution: 0.1L/min, Maximum permitted error: ±1L/min

Parameter range: 90L/min, Resolution: 0.1L/min, Maximum permitted error: ±1L/min

Parameter range: 85L/min, Resolution: 0.1L/min, Maximum permitted error: ±1L/min

Parameter range: 45 L/min, Resolution: 0.1L/min, Maximum permitted error: ±1L/min

Parameter range: 30 L/min, Resolution: 0.1L/min, Maximum permitted error: ±1L/min

Pressure range: Parameter range: ±2000Pa, Resolution: 1Pa, Maximum permitted error: ±2Pa

Data storage: 1000000 groups

Dimension(W×D×H:(400×300×250)mm

Overall weight: About 8.8kg

Overall power: <250W

Product Detail

ZR-1211 mask resistance tester is used to test inhalation and exhalation resistance of masks in regulated test condition. Compatible  to multiple flow rates, is suitable to perform related inspection and test of masks for mask manufacturers, national inspection institutes of labor protection devices.

Standards

GB 2626-2019 Respiratory protective equipment Non-powered air-purifying particle respirator

GB/T 38880-2020 Technical specification of children mask

GB/T 32610-2016

EN 149:2001-10 Respiratory protective devices - Filtering half masks to protect against particles - Requirements, testing, marking

ASTM F2100-2111 Standard Specification for Performance of Materials Used in Medical Face Masks

Features

> Standard head form conforms to requirements in annex B of GB 2626-2019, optional multiple types of head forms.

> 7-inch high definition touch screen.

> Electric flow meter,high precision flow control.

> Automatic constant flow control, compatible to 30,40,45,85,90,95,160 L/min multiple flow rate.

> Separately test inhalation and exhalation resistance.

> Large-capacity data storage, real time save test data.

> Support export to USB flash dish or print real-time of historical data with thermal printer.

> Automatically judge whether the sample is qualified.

> Automatic failure protection.

혜택 소식 받아보기

대량 할인, 도매 가격 업데이트 및 신제품 소식을 이메일로 받아보세요.

구독하면 당사의 서비스 이용약관개인정보 처리방침에 동의하는 것으로 간주됩니다.

빠른 지원

인증된 전문가에게 직접 연결