For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

Junray ZR-3260DA 스마트 먼지(가스) 테스터 (0~110L/min, 60~130kPa)

문의하기
안전한 결제
품질 보장
간편 교환 및 반품
배송 가능

Dust technical parameter

Sampling flowrat: Range: (0~110)L/min, Resolution: 0.1L/min, Error: ±2.5%

Flowrate control: ±2.0%(voltage change ±20%,resistance range:3kpa—6kpa)

Dynamic pressure: Range: (0~2000)Pa, Resolution: 1Pa, Error: ±1.0%FS

Static pressure: Range: (-30~30)kPa, Resolution: 0.01kPa, Error: ±1.0%FS

Total pressure: Range: (-30~30)kPa, Resolution: 0.01kPa, Error: ±2.0%FS

Flowrate pre-meter pressure: Range: (-60~0)kPa, Resolution: 0.01kPa, Error: ±1.0%FS

Flowrate pre-meter temperature: Range: (-55~125)℃, Resolution: 0.1℃, Error: ±2.5℃

Velocity range: Range: (1~45)m/s,  Resolution: 0.1m/s,  Error: ±4.0%

Atmospheric pressure: Range: (60~130)kPa, Resolution: 0.1kPa,  Error: ±0.5kPa

Auto tracking Precision: Range: -, Resolution: -, Error: ±3%

Max sampling volume: Range: 99999.9L, Resolution: 0.1L, Error: ±2.5%

Isokinetic trackingresponse time: ≤10s

Load capacity of pump: ≥50L/min(when resistance is 30 PA)

Size: (L275×W170×H265)mm

Weight: About 6.8kg(battery include)

Noise: <65dB(A)

Power consumption: <300W


Flue gas technical index

Sampling flow: Range: 1.0L/min, Resolution: 0.1L/min, Error: ±5%

O2(optional): Range: (0~30)%, Resolution: 0.1%, Error: Indication error:±5%Repeatability:≤1.5%Response time:≤90sStability:change within 1hExpected life:2 years in air (beside CO2)

SO2(optional):  Range: (0~5700)mg/m3  Can extend to 14000mg/m³,  Resolution: 1mg/m3, Error: Indication error:±5%Repeatability:≤1.5%Response time:≤90sStability:change within 1hExpected life:2 years in air (beside CO2)

NO(optional): Range: (0~1300)mg/m3  Can extend to 6700mg/m³,  Resolution: 1mg/m3, Error: Indication error:±5%Repeatability:≤1.5%Response time:≤90sStability:change within 1hExpected life:2 years in air (beside CO2)

NO2(optional):  Range: (0~200)mg/m3  Can extend to 2000mg/m³, Resolution: 1mg/m3, Error: Indication error:±5%Repeatability:≤1.5%Response time:≤90sStability:change within 1hExpected life:2 years in air (beside CO2)

CO(optional): Range: (0~5000)mg/m3  Can extend to 25000mg/m³, Resolution: 1mg/m3, Error: Indication error:±5%Repeatability:≤1.5%Response time:≤90sStability:change within 1hExpected life:2 years in air (beside CO2)

H2S(optional): Range: (0~300)mg/m3  Can extend to 1500mg/m³, Resolution: 1mg/m3, Error: Indication error:±5%Repeatability:≤1.5%Response time:≤90sStability:change within 1hExpected life:2 years in air (beside CO2)

CO2(optional):  Range: (0~20)%, Resolution: 0.01%, Error: Indication error:±5%Repeatability:≤1.5%Response time:≤90sStability:change within 1hExpected life:2 years in air (beside CO2)

Product Detail

It adopts isokinetic sample and membrane filter (cartridge) weighing method to measure dust concentration while using electrochemistry or optical principle sensor  to analyze O2, SO2, CO, NO, NO2, H2S, CO2. And also the velocity of flue gas, flue gas temperature, flue gas humidity,  flue pressure and exhaust air rate etc.

Standards

EN13284-1

US EPA M5

US EPA M17

ISO 9096

혜택 소식 받아보기

대량 할인, 도매 가격 업데이트 및 신제품 소식을 이메일로 받아보세요.

구독하면 당사의 서비스 이용약관개인정보 처리방침에 동의하는 것으로 간주됩니다.

빠른 지원

인증된 전문가에게 직접 연결