For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

KYORITSU 8035 비접촉 안전 상 표시기 (70~1000V AC)

Model8035
원산지Thailand
부가세 별도
6,589,500 VND
부가세 포함
7,116,660 VND
안전한 결제
품질 보장
간편 교환 및 반품
배송 가능

New technology permits safe testing, without the need of direct contact between probes and live wires.
The insulated crocodile clips can clip insulated cables from φ2.4 to 30mm.
Phase rotation is indicated by the rotary illumination of LEDs and logical audible tones.
The instrument can be fixed to a metal panel via the magnet on the back side.
Wide measuring range for 3 phase installations from 70V to 1000V AC.
Super brightness function permits clear LED is indication also in sunshine.
Complies with IEC 61010-1 CAT.IV 600V and CAT.III 1000V.

 

New technology permits safe testing, without the need of direct contact between probes and live wires.
The insulated crocodile clips can clip insulated cables from φ2.4 to 30mm.
Phase rotation is indicated by the rotary illumination of LEDs and logical audible tones.
The instrument can be fixed to a metal panel via the magnet on the back side.
Wide measuring range for 3 phase installations from 70V to 1000V AC.
Super brightness function permits clear LEDs indication also in sunshine.
Complies with IEC 61010-1 CAT.IV 600V and CAT.III 1000V.

NEW
8035
CE
Functions Phase rotation (Clockwise or Counter Clockwise),
Presence of open phase
Detection method Electrostatic induction
Measuring voltage range From 70 to 1000V AC phase to phase (sine wave, continuous input)
Clamp diameter range From φ2.4 to 30mm insulated cables
Measuring frequency range 45 to 66Hz
Phase rotation
Clockwise:
Green arrow LEDs "rotate" in clockwise, Green symbol "CW" lits, Intermittent buzzer
Counter Clockwise:
  Red arrow LEDs "rotate" in counter clockwise, Red symbol "CCW" lits, continuous buzzer
Visual indication Via LEDs with Super brightness function
Battery voltage warning Power LED blinks if battery voltage is too low.
Operating conditions Temperature/Humidity Ranges -10 to 50ºC, 80% (no condensation)
Storage conditions Temperature/Humidity Ranges -20 to 60ºC, 80% (no condensation)
Applicable standards IEC 61010-1 CAT.IV 600V, CAT.III 1000V Pollution degree2,
IEC 61326-1, IEC 61557-1, -7
Power supply Alkaline battery (LR6) ×4
* Continuous use: Approx. 100 hours (Auto power off in about 10 min.)
Dimensions 112(L) × 61(W) × 36(D) mm
Weight Approx. 380g
Test leads Double insulated cables, length approx. 70cm
Colours code L1(U): RedL2(V): WhiteL3(W): Blue
Accessories included 9096 (Carrying case), Alkaline battery (LR6) × 4, Instruction manual