Labkotec LID-3300IP Ice Detector (4-20mA, Modbus TCP/IP, PLd)
Control Unit
Enclosure:
Dimensions: 125 x 175 x 75 mm (hxw x d)
Weight: 1 kg
Material: Polycarbonate
Degree of protection: IP 65
Temperature: -30 °C...+55 °C
Max. altitude above sea level: 4000 m
Power supply: 230 VAC ±10%, 50/60 Hz. Recommended fuse size in the supply line is 10 A, maximum 16 A.
Power consumption: Normally 7 VA. Max 350/500 W during sensor heating
Fuses: (1) 50 mAT, (2) and (3) 4 AT, IEC 127 5 x 20 mm
Analog outputs: 2 pcs, active and galvanic isolated current output 4-20 mA to max. 1 k load (for Ice signal and temperature). Connector numbers 11 - 14.
Relay outputs:
2 pcs (Ice alarm and fault), potential free relay output. Connector numbers 5-10.
Umax = 120VDC (ripple-free) or 50VAC
Imax = 1A
Front panel: LED indication for Power, Ice Alarm, Heating and Fault. Test button to simulate Ice Alarm.
Serial outputs: one RS-232 and one TTL/Optical fibre
Ethernet: Integrated web server and web based user interface for remote access to Ice Detector via Internet. Galvanic isolated standard RJ-45 connector. Network settings can be configured via RS-232. Default IP address: 192.168.1.88. Modbus TCP/IP
LID/ISD Type 2 Ice Sensor
Dimensions: 350 x 100 x 25 mm (h x w x d)
Weight: 1.3 kg (1.7 kg with standard mounting kit)
Material: Aluminum
Protection: IP 65
Temperature: -40 °C...+60 °C
Max. altitude above sea level 4000 m
Cable diameters:
Signal cable: 7.5 mm
Heating cable: 11.5 mm
인증된 전문가에게 직접 연결