Labkotec SET-61 Dry-Boiling Preventer (+10 % -15 %; 4 VA)
Dry-Boiling Preventer
Operation voltage: 230 V (115 V) 50-60 Hz, 4VA.
Fuse IEC 127 5x20mm/160mAT, II-Class The unit does not contain isolating switch (isolator).
Max. voltage alteration: +10 % -15 %
Power consumption: 4 VA
Operating temperature: -10°C...+50°C
Electrode connection
- voltage: max. 24 V / 50 Hz
- short-circuit current: < 3 mA
- operating range (conductivity): 1/50 kS ... 1/100 kS
Cable type: With a device is delivered probe`s a coupling cable 5m:
LABKO SET60S/PSP4E cable
Silicone cable 2 x 0.75 mm² + shield
Outputs:
2 relay outputs with potential-free
switch contacts (SPDT): 250 V / 5 A
During normal operation relays are energized
and they are released at the alarm.
Enclosure
- Classification: IP 65
- Dimensions: 180 x 130 x 75 (w x h x d)
- Material: Polycarbonate