For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0

NOVOTEST DPM LAB dew point meter for coating and application condition testing

2025년 11월 15일 09시 44분 59초

The NOVOTEST DPM LAB dew point meter is designed for technicians who need to monitor environmental conditions before coating application, paint spraying or surface acceptance.

The device simultaneously displays air temperature, humidity, dew point, surface temperature and Delta T difference to assess the safety of the surface at each time. This is a key factor to limit the risk of condensation causing peeling or spreading of the coating after completion.

Monitor dew point and evaluate surfaces using direct measurement data

The DPM LAB Dew Point Meter  continuously collects environmental parameters, from which the dew point and Delta T difference are calculated to determine the risk of condensation. As the surface approaches the dew point, the coating is more likely to lose adhesion and develop defects. Technicians can rely on Delta T to decide the appropriate application time.


The bright display of the NOVOTEST DPM LAB supports reading data in sunlight or in areas with strong reflections. The user can choose to display each parameter in large format or view all parameters on one interface, suitable for quickly checking many consecutive locations. Evaluating the coating application conditions becomes more intuitive, especially in outdoor areas or newly cleaned surfaces.

NOVOTEST Lab App for measurement management and construction reporting

NOVOTEST DPM LAB is at its best when combined with the NOVOTEST Lab App. The app allows you to record your measurements with photos and videos, create automatic reports, and synchronize data to the cloud. Each measurement value can be annotated with voice, image, or video to clearly describe the location or surface condition.

In projects with multiple construction teams, dew point meter data is easily shared with QA or site commanders via a communication application. Measurement history by area helps control progress and compare environmental conditions in previous shifts. When retrieval is needed, technicians can simply open the archived data without having to manually summarize.

The voice reading feature is useful when working in dark spaces or when wearing gloves. Measurement management becomes consistent, especially for projects that require transparent reporting of environmental conditions before painting or coating surfaces.

Site-appropriate design and flexible operation

The body of the DPM LAB is easy to hold and suitable for continuous operation on large surfaces. The device uses AAA batteries, convenient to carry spares and ensure operation for a full shift. The screen has high brightness, making data readable even in bright sunlight.

The USB C port is used for software updates and checking the device during maintenance. These factors help the dew point meter operate stably in industrial environments, where conditions fluctuate greatly and require the instrument to respond quickly when moving between multiple areas.

New sensor measures quickly and is suitable for many types of surfaces

The DPM LAB version uses a new generation of temperature and humidity sensors that register environmental changes more quickly. This is important when the operator is between a hot work area and a cold windy area or when inspecting outdoor construction sites.

Infrared surface temperature probes are fast-responsive and less dependent on the reflectivity of the material. Technicians can measure freshly cleaned steel, primer-coated materials, or low-gloss surfaces and still receive stable readings. When checking the condition of coatings, more accuracy is achieved, especially in projects requiring strict quality control.

관련 뉴스

Insulation Resistance Tester: Procedures and Safety Precautions
2026년 08월 25일 09시 05분 54초

A megohmmeter must be used according to the proper procedure to ensure operator safety and reliable measurement results. This article covers its operating principle, testing procedure, influencing factors, and essential safety precautions.

How to Measure Ground Resistance Effectively
2026년 08월 25일 09시 02분 07초

A ground resistance tester is used to measure the resistance of a grounding system or ground electrode. Using the correct measurement method gives operators a better basis for identifying changes in the system over time and taking appropriate inspection or corrective measures.

DC Resistance Meter and Considerations When Testing Electrical Equipment
2026년 08월 25일 09시 00분 32초

DC resistance meters are commonly used to evaluate current paths, windings, and contact points characterized by low resistance. The results depend not only on the test object itself but also on the connection configuration, thermal state, inductive characteristics of the windings, and the current injection process.

DC Resistance Meter: Principles and Applications
2026년 08월 25일 08시 58분 25초

DC resistance meter is commonly used in electrical equipment maintenance and system safety testing to evaluate the condition of windings, conductors, and electrical connections.