MCB Electronics PF-10-TS-T-V05-A2000 Power-Flow - AC/DC Current Generator (10 kVA)
Power: 10 kVA
Transformer: Isolation transfomer
Full Load Efficiency: > 93%
Input Connection: Standard Terminal blocks
Output Connection: Custom terminal blocks
VOLTAGE
Input Range [PH-PH]: 350 – 440 Vac
Output [PH-N]: 1 - 5Vac
Regulation System [PH-PN]: Adjustable within the output voltage range
Sensing Function: Yes driven in current. MCB036 board with current sensors.
Total Harmonic Distortion [THD]: < 0,5%
Static Line Regulation: < 1%
Static Load Regulation: < 1%
Dynamic stability of the output voltage upon load variation: < 0.2% with 100ms stabilization time in thermic curve
CURRENT
Output and Regulation: single range from 30A to 2000A
FREQUENCY
Input Range: 47Hz - 63Hz
Output [switchable from control panel and remote]: 50Hz and 60Hz [± 0,01%]
Output [adjustable from control panel and remote]: from 40Hz to 80Hz [± 1%]
OTHERS
Noise level: 60dBA
Power Protections: OVP, UVP, OCP, OTP
CONTROL PANEL
Commands: LCD display 4 x 40 characters + command buttons
Voltage and current LCD Display accuracy: ± 2 DIGIT
Voltage LCD Display resolution: ± 0.5Vac
Current LCD Display resolution: ± 1A
Frequency value visualization: Yes
Output Current Value Visualization: Yes
COMMUNICATION INTERFACES
Analog: MCB owned I/O 12 poles equipped with 0-10Vdc
RS232: Yes
Ethernet: Yes
Communication Protocols: 0-10Vdc over analog I/O 12 poles & SCPI over RS232 and Ethernet
Reference Voltage of remote controls: Common ground with ground line
MECHANICAL
Dimensions (W x H x D): 550 x 1100 x 800 mm
Weight: 175kg
ENVIRONMENTAL
Cooling: Air Forced Circulation
Operating Temperature: from 0° to +40°C
Storage Temperature: from -40° to +85°C
REGULATORY
Safety: EN 61000-6-2 (2005) + AC (2005), EN 61000-6-4 (2007)+A1(2011), EN 61010-1 (2010) + A1/AC (2019)
EMC: 2014/35/UE (LVD), 2014/30/UE(EMC)
인증된 전문가에게 직접 연결