MCB Electronics PF-DC-2.5-S-R-V05-A500 Power-Flow - AC/DC Current Generator (2.5 kW)
Power: 2.5 kW
Transformer: Isolation transformer + diode bridges
Full Load Efficiency: > 89%
Input Connection: Standard Terminal blocks
Output Connection: Custom sized copper bars in the rear of the unit
VOLTAGE
Input Range [PH-N]: 190 – 267 Vac
Output [DC]: 5 Vdc
Regulation System [PH-N]: Non Adjustable
Sensing Function: Yes driven in current. MCB104 board with current sensors.
Total Harmonic Distortion [THD]: < 0,5%
Static Line Regulation: < 1%
Static Load Regulation: < 1%
Dynamic stability of the output voltage upon load variation: < 0.2% with 100 ms stabilization time with thermic curve
CURRENT
Output and Regulation: Single Range 25 A - 500 A
FREQUENCY
Input Range: 47 Hz - 63 Hz
Output [switchable from control panel and remote]: -
Output [adjustable from control panel and remote]: -
OTHERS
Noise level: 60 dBA
Power Protections: OVP, UVP, OCP, OTP
CONTROL PANEL
Commands: LCD display 4 x 40 characters + command buttons
Voltage and current LCD Display accuracy: ± 2 DIGIT
Voltage LCD Display resolution: No relevant in this case since there's no voltage regulation
Current LCD Display resolution: ± 1 A
Frequency value visualization: -
Output Current Value Visualization: Yes
COMMUNICATION INTERFACES
Analog: MCB owned I/O 12 poles equipped with 0-10 Vdc
RS232: Yes
Ethernet: Yes
Communication Protocols: 0-10 Vdc over analog I/O 12 poles & SCPI over RS232 and Ethernet
Reference Voltage of remote controls: Common ground with ground line
MECHANICAL
Dimensions (W x H x D):
Inverter + Isolation Transformer: 1 x [3U D540 including 40 mm handles]
Diode Bridges + Extra heat sink + Extra wiring/terminals + Extra current transducer: 1 x [3U D560 including 40 mm handles]
Weight: 60 kg
ENVIRONMENTAL
Cooling: Air Forced Circulation
Operating Temperature: from 0° to +40°C
Storage Temperature: from -40° to +85°C
REGULATORY
Safety: EN 61000-6-2 (2005) + AC (2005), EN 61000-6-4 (2007)+A1(2011), EN 61010-1 (2010) + A1/AC (2019)
EMC: 2014/35/UE (LVD), 2014/30/UE (EMC)