2026년 09월 23일 15시 15분 18초

Duplex systems pair a barrier coating with zinc protection. PosiTector 6000 FNDS measures the paint and zinc layers individually in a single reading by combining magnetic and eddy-current measurement principles.

Paint coating thickness gauge separates the paint layer and zinc layer on galvanized steel. The PosiTector 6000 FNDS is designed to display these individual layer thicknesses from a single non-destructive reading.

This approach addresses a key limitation of methods that calculate one layer by subtracting readings: zinc thickness can vary across a galvanized part or structure.

Handheld PosiTector 6000 FNDS coating thickness gage
PosiTector 6000 FNDS1

What is a duplex coating system?

A duplex coating system typically combines paint or powder coating over galvanized steel. It brings together zinc-based cathodic protection and a barrier coating intended to limit electrolyte contact with the steel.

Steel corrosion occurs when an electrolyte connects anodes and cathodes on the steel surface, forming a corrosion cell that produces rust. Zinc acts as a sacrificial anode, while paint or another protective coating provides a barrier.

  • Galvanizing may be hot-dip, electro, or zinc spray metallizing.
  • The outer paint or powder layer can provide color coding and an aesthetic finish.
  • The combined system can extend the life of the coating system and underlying substrate, while delaying maintenance and touch-up needs.

Why must paint and zinc thickness be measured separately?

Separate paint and zinc measurements help evaluate the individual layers in a duplex system rather than only the total coating build. This is important because galvanized zinc thickness is not necessarily uniform over an entire component or structure.

The thickness, roughness, chemistry, and design of the steel being galvanized can affect the resulting zinc coating thickness. A calculation based on an assumed constant zinc layer may therefore not represent conditions at every measurement location.

Electrical transmission tower with a duplex coating system

How do conventional duplex thickness methods work?

Conventional methods commonly use two measurements and a subtraction calculation. One approach uses a magnetic coating thickness gage, such as PosiTector 6000 F1 or PosiTest DFTF, to measure zinc thickness and then the total paint-plus-zinc thickness; the difference is treated as paint thickness.

Another approach uses a combination magnetic and eddy-current probe such as PosiTector 6000 FN3. An eddy-current reading is used for paint thickness, a magnetic reading provides total system thickness, and the difference is treated as zinc thickness.

Both approaches depend on an assumption that the zinc thickness does not vary across the structure. They also require two readings and a calculation for each measurement point.

How does PosiTector 6000 FNDS1 measure duplex coating thickness?

In Duplex mode, PosiTector 6000 FNDS1 uses magnetic and eddy-current principles simultaneously to calculate and display the individual paint and zinc layer thicknesses. The measurement is non-destructive and obtained in one reading.

The magnetic principle measures the combined paint-and-zinc thickness over a ferrous substrate. The eddy-current principle measures paint thickness over the non-ferrous zinc coating, then the instrument calculates zinc thickness by subtracting paint thickness from the combined measurement.

Diagram showing individual paint and zinc layer thicknesses in a duplex coating system

When can PosiTector 6000 FNDS1 be used outside Duplex mode?

Outside Duplex mode, PosiTector 6000 FNDS1 operates as a conventional combination ferrous/non-ferrous instrument, similar to a PosiTector 6000 FNS probe. It is intended for measuring non-magnetic coatings over steel and non-conductive coatings over non-ferrous metal substrates.

The appropriate mode depends on the coating stack being inspected. Duplex mode applies where paint is present over zinc on a ferrous steel substrate; conventional combination operation applies to the stated ferrous and non-ferrous substrate applications.

What should be considered when selecting a duplex thickness measurement method?

Select a method based on whether individual paint and zinc values are needed at each location and whether variation in zinc thickness must be considered. A one-reading duplex measurement avoids relying on a fixed zinc-thickness assumption in the subtraction methods described above.

For inspection work, the measurement method should also match the substrate and coating arrangement. Distinguishing ferrous steel, non-ferrous zinc, and the outer coating layer is central to the measurement principles used by PosiTector 6000 FNDS1.

관련 뉴스

SiC/GaN Semiconductor Material Trends: From Materials Research to In-Depth Failure Analysis
2026년 10월 24일 09시 59분 14초

As we enter the 2026–2030 period, wide-bandgap (WBG) semiconductor materials such as Silicon Carbide (SiC) and Gallium Nitride (GaN) are transforming the power electronics, electric vehicle (EV/HEV), renewable energy, and AI data center industries. The shift from traditional silicon to SiC and GaN enables higher power density, smaller passive components, and improved overall system energy efficiency.

Chauvin Arnoux C.A 6117 Multifunction Electrical Installation Tester
2026년 10월 23일 15시 26분 05초

An all-in-one testing solution that complies with the international standard IEC 60364-6. It features a 5.7-inch color graphical display, supports Type B RCD testing, includes memory for 1,000 measurements, and is equipped with a Lithium-ion battery providing 30 hours of continuous operation

Plastic Products with Color Streaks: How to Adjust Back Pressure and Screw Speed? How Should Color Be Measured to Verify Proper Adjustment?
2026년 10월 21일 15시 30분 17초

In the middle of the night shift, a batch of light-gray plastic emerged, streaked with debris. The machine operator took one look and did what came most naturally: he cranked up the screw speed and increased the back pressure to ensure the orange-colored pellets melted completely. By morning, the color was indeed more uniform. A few weeks later, the customer returned the entire shipment the products had become brittle, cracking at the slightest impact, and the color varied from one delivery to the next, failing to match the approved standard

혜택 소식 받아보기

대량 할인, 도매 가격 업데이트 및 신제품 소식을 이메일로 받아보세요.

구독하면 당사의 서비스 이용약관 및 개인정보 처리방침에 동의하는 것으로 간주됩니다.

빠른 지원

인증된 전문가에게 직접 연결