Metrel MD 9226 Clamp Meters (TRMS,600.0 V; 600.0 A)
DC Voltage:
Range: 600.0 V, Accuracy: ±(1.0% of reading + 5 digits)
AC Voltage (50 Hz … 60 Hz):
Range:600.0 V
Accuracy:±(1.0% of reading + 5 digits)
DC+AC Voltage (DC, 50 Hz … 60 Hz):
Range:600.0 V
Accuracy:±(1.2% of reading + 7 digits)
Audible Continuity Tester: Audible threshold between 10 Ω and 250 Ω / Response time approx. 32 ms
Resistance:
Range:600.0 Ω, 6.000 kΩ, 60.00 kΩ
Accuracy:±(1.0% of reading + 5 digits)
Capacitance:
Range:200.0 µF, 2500 µF
Accuracy:±(2.0% of reading + 4 digits)
Diode Tester:
Range:2.000 V
Accuracy:±(1.5% of reading + 5 digits)
AmpTip™ Clamp-on ACA (50 Hz … 60 Hz):
Range:60.00 A
Accuracy:±(1.5% of reading + 5 digits)
AmpTip™ Clamp-on DCA:
Range:60.00 A
Accuracy:±(2.0% of reading + 5 digits)
AmpTip™ Clamp-on DC+ACA (DC, 50 Hz … 60 Hz):
Range:60.00 A
Accuracy:±(2.0% of reading + 7 digits)
Regular Clamp-on ACA (50 Hz … 400 Hz):
Range:60.00 A … 600.0 A
Accuracy:From ±(1.8% of reading + 5 digits) to ±(2.0% of reading + 5 digits)
Regular Clamp-on DCA:
Range:60.00 A … 600.0 A
Accuracy:±(2.0% of reading + 5 digits)
Regular Clamp-on DC+ACA (DC, 50 Hz … 400 Hz):
Range:60.00 A … 600.0 A
Accuracy:From ±(2.2% of reading + 7 digits) to ±(2.7% of reading + 7 digits)
Hz Line Level Frequency:
Range:5.00 Hz … 999.9 Hz
Accuracy:±(1.0% of reading + 5 digits)
Non-Contact EF Detection: 20 V … 440 V
Detection frequency 50/60 Hz
Transient Protection: 6.0 kV (1.2/50 µs surge)
Power Supply: 2 × 1.5 V AAA batteries
Power Consumption: 13 mA
Dimensions: 223 × 76 × 37 mm
Weight: 234 g
Jaw Opening & Conductor Diameter: 35 mm