Range/ Accuracy
DC Voltage: 6.000 V … 1500 V / ±(0.5% of reading + 5 digits)
AC Voltage (50 Hz ... 400 Hz): 6.000 V … 1000 V / ±(1.2% of reading + 5 digits)
AC+DC Voltage (DC, 50 Hz ... 400 Hz): 6.000 V … 1000 V / ±(1.4% of reading + 7 digits)
Variable Frequency Drive AC: 10 Hz … 400 Hz / ±(4.0% of reading + 80 digits)
DC Current: 200.0 A … 2000 A / ±(2.0% of reading + 5 digits)
AC Current (50 Hz ... 400 Hz): 200.0 A … 2000 A / ±(2.0% of reading + 5 digits)
Resistance: 600.0 Ω … 40.00 MΩ / ±(0.5% of reading + 5 digits)
Capacitance: 60.00 nF … 2000 µF / ±(2.0% of reading + 5 digits)
Temperature:
-50 °C … 1000 °C / ±(0.3% of reading + 4 digits)
-58 °F … 1832 °F / ±(0.3% of reading + 6 digits)
Mains Frequency: 10 Hz … 1999 Hz / ±(0.1% of reading + 4 digits)
Diode Test: 1.000 V / ±(1.0% of reading + 3 digits)
Power Supply: 2 × 1.5 V AA batteries (IEC LR6)
Overvoltage Category: CAT IV / 1000 V, CAT III / 1500 V
Dimensions: 264 × 97 × 43 mm
Weight: 608 g
Display:
3-5/6 digits, 6000 counts
3-1/2 digits, 1,999 counts (Hz)
Overload Protections:
- Clamp-on jaws 2000 A rms continuous
- Voltage on terminals 1650 V DC / 1100 V AC rms
- Other functions 1500 V DC / 1000 V AC rms
E.M.C.: Meets EN61326-1:2006
- In an RF field of 3V/m Capacitance function is not specified
- Other function ranges Total Accuracy = Specified Accuracy + 200 digits
- Performance above 3V/m not specified
Power Consumption: Typical 14 mA (Current functions), 5.2 mA (Other functions)