Micrometer size failed? How to edit instructions

2024년 08월 23일 16시 00분 05초

The micrometer is used to measure with quite high accuracy, but after a long period of use, there are many reasons why the measuring lines on the micrometer no longer match accurately. So how to effectively adjust the error of the micrometer? Follow EMIN in the article below!

Zero error of the micrometer and how to fix it

The cause of 0 error in mechanical measuring tools is often due to external factors such as falling, impact leading to warping, rust, or wear of the device after long-term use. In addition, zero error can also come from the user's incorrect calibration or not knowing how to calibrate correctly, inaccurate measurement operations, or due to parallax problems - a phenomenon that occurs when the viewing angle is not correct. causing misreading errors.

Error 0 can be due to many different reasons, not only due to external influences. Usually this error occurs in two cases:

1. If the zero line of the Vernier scale is below the main scale, this error is called positive zero error.

2. If the zero line of the Vernier scale is on the main scale, this error is called negative zero error.

Zero error directly affects the measurement result, so if the error is not too large, you can simply adjust the measurement result by adding (with negative zero error) or subtracting (with positive zero error). ) with ruler precision. However, when high precision is required, professional micrometer calibration is necessary.

How to fix the error of dividing lines on the micrometer that do not match

Thimble (secondary ruler), plays an important role in determining correct measurement results. When the micrometer encounters an error where the division lines do not match, you can adjust them so that the 0 lines on the main scale and sub-meter match.

First, turn the knob so that the two measuring heads of the micrometer touch each other. Use the locking screw to fix the micrometer to avoid movement during adjustment. Next, use a small wrench to tighten the main ruler. After doing this, check to see if the 0 lines on the main ruler and the secondary ruler coincide.

If the divisions still do not match, it may be due to a zero error. At this time, it is necessary to continue to recalibrate to ensure accurate measurement results according to the requirements of the job.

Related articles: Principles for choosing a micrometer for beginners

How to preserve and clean the micrometer to prolong its life

Proper cleaning and storage not only helps minimize errors when using a micrometer but also prolongs the life of the device, helping it to operate stably throughout the measurement process.

Clean the micrometer properly

To avoid errors such as zero or error, you need to clean the micrometer before and after use. Basic cleaning can only remove surface dust and dirt without completely eliminating factors that can cause errors.

Before use, check the anvil and spindle of the micrometer to ensure they are aligned and not dented. Gently clamp a clean sheet of paper between the surfaces, then pull the paper out to clean. Next, gently close the micrometer and check the thimble to see if the 0 lines on the main scale and sub-scale match.

After use, wipe the micrometer with a clean cloth moistened with a little oil to protect the surfaces from dirt and oxidation.

Store the micrometer properly

Periodically check and calibrate the micrometer to ensure no errors occur during the measurement process. Before and after use, wipe with a soft cloth to remove dirt from the micrometer surfaces. Apply a thin layer of oil after each use to prevent rust and help parts move smoothly.


After use, store the micrometer in a dry place, away from moisture. Do not stack instruments on top of each other to avoid damaging or affecting the function of the micrometer.

관련 뉴스

Is Ultrasonic Welding Waterproof? Find out with the experts!
2026년 07월 07일 10시 35분 50초

Water resistance is a common requirement for a wide range of modern products, spanning industrial sensors, outdoor LED lights, medical devices, and water filter cartridges to electronic components and automotive parts. When exploring manufacturing technologies, many businesses often ask the same question: can ultrasonic welding truly create a watertight seal?

Why Is the Ultrasonic Weld Not Airtight? Causes and Solutions
2026년 07월 07일 09시 47분 07초

A satisfactory ultrasonic weld must form a uniform bond across the entire contact surface. The presence of gaps, edge separation, or partial adhesion significantly compromises airtightness, watertightness, and mechanical strength. This is a common issue in the manufacturing of plastics, electronic components, packaging, and medical devices, particularly following a product changeover or an adjustment of welding parameters on the production line.

What Do Surface Resistances of 10⁶, 10⁹, and 10¹² Ω Signify?
2026년 07월 03일 15시 33분 05초

What do surface resistance values ​​of 10⁶, 10⁹, and 10¹² Ω signify? Distinguish between conductive, static-dissipative, and insulating materials to select the appropriate ESD materials and evaluate them according to standards.

혜택 소식 받아보기

대량 할인, 도매 가격 업데이트 및 신제품 소식을 이메일로 받아보세요.

구독하면 당사의 서비스 이용약관개인정보 처리방침에 동의하는 것으로 간주됩니다.

빠른 지원

인증된 전문가에게 직접 연결