Microorganisms in Wastewater Treatment Plants Die: Causes and Solutions for Complete Remediation

2026년 10월 06일 16시 27분 48초

Wastewater treatment plants use aerobic tanks to break down pollutants. Biological problems occur when the sludge turns black with surface foam, causing effluent water parameters to exceed permissible limits. Addressing this situation requires engineers to measure core environmental parameters instead of adding random probiotics

Dead Microorganisms in Wastewater Treatment Plants: Causes & Emergency Recovery

Wastewater treatment plants rely on aerobic tanks to break down pollutants. Biological system failures occur when sludge turns black accompanied by surface foam, causing discharge parameters to exceed allowable limits. Resolving this issue requires engineers to measure core environmental parameters rather than adding random bio-products.

Check 3 Critical Parameters with Measurement Instruments

Dissolved Oxygen (DO) Concentration

Standard Range: 2.0 - 4.0 mg/L

Dissolved oxygen concentration plays a vital role in maintaining respiration for activated sludge. Standard values range from 2.0 to 4.0 mg/L. Oxygen levels dropping below 1.5 mg/L lead to anoxic conditions, reducing efficiency and turning sludge black. Values exceeding 5.0 mg/L waste energy and break floc structures due to excessive agitation. Portable measuring devices enable direct testing at each location to accurately assess aeration efficiency.

Wastewater pH Index

Standard Range: 6.5 - 8.5 pH

The pH index reflects the stability of the influent stream. The optimal pH range lies between 6.5 and 8.5. Sudden fluctuations caused by acidic or alkaline chemicals push pH outside the safe range, damaging microbial communities. Dedicated pH meters placed directly in the stream provide continuous data to detect fluctuations promptly.

Nutrient Ratio (BOD : N : P)

Golden Ratio: 100 : 5 : 1

Nutrient ratios must be maintained according to the formula 100 : 5 : 1. Industrial wastewater often lacks organic carbon or contains excess pollutants. COD measurement devices quantify incoming organic loads, establishing a precise baseline for adding molasses or compounds containing nitrogen and phosphorus.

4-Step Emergency Biological Tank Recovery Process

1
Step 1: Isolate & Remove Damaged Sludge

Isolate the system, turn off aeration, and discharge the damaged sludge into the sludge holding tank to prevent contamination from spreading to downstream tanks.

2
Step 2: Adjust Water Environment to Standard

Engineers use pH meters to test and neutralize water to a range of 7.0 to 7.5, then restart the air blowers until the dissolved oxygen (DO) level exceeds 2.0 mg/L.

3
Step 3: Inoculate Biomass & Supplement Nutrients

Add fresh biomass alongside nutrient sources (molasses, Urea, DAP) based on calculations of actual organic loading.

4
Step 4: Maintain Continuous Monitoring

Continuously monitor parameters including temperature, pH, dissolved oxygen, and sludge settling volume (SV30) daily using portable instruments to track microbial growth rates.

Field Measurement Solutions from EMIN Vietnam

Genuine portable measurement instruments help engineers measure field parameters quickly, eliminating laboratory analysis delays and ensuring wastewater treatment system stability.

관련 뉴스

Causes of gas sensor errors
2026년 11월 21일 09시 15분 27초

this silent loss of sensitivity typically stems from selecting the wrong sensing principle for the local chemical composition and atmospheric conditions. To effectively deploy equipment from our fixed gas detectors catalog, M&E engineers and HSE teams must understand the mechanisms behind catalytic sensor poisoning and identify the appropriate alternative technologies for each operating environment.

Giải pháp giám sát khí rò rỉ chống cháy nổ cho nhà xưởng
2026년 11월 20일 15시 11분 51초

Đối với đội ngũ kỹ sư cơ điện (M&E), bộ phận an toàn môi trường (HSE) và chủ đầu tư nhà máy, việc nắm rõ các yêu cầu mới không chỉ giúp hoàn thiện hồ sơ pháp lý mà còn định hình lại tiêu chuẩn lựa chọn hệ thống máy đo khí lắp cố định tại các khu vực có nguy cơ cháy nổ cao.

혜택 소식 받아보기

대량 할인, 도매 가격 업데이트 및 신제품 소식을 이메일로 받아보세요.

구독하면 당사의 서비스 이용약관 및 개인정보 처리방침에 동의하는 것으로 간주됩니다.

빠른 지원

인증된 전문가에게 직접 연결