For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

OMEGA OM-CP-RFPRHTEMP2000A 무선 압력, 습도 및 온도 데이터 로거 디스플레이 포함 (60 °C, 0 to 95% RH, Wall Mount)

ModelOM-CP-RFPRHTEMP2000A
문의하기
안전한 결제
품질 보장
간편 교환 및 반품
배송 가능

Width: 3.5 in

Height: 0.95 in

Length: 3 in

Weight: 4.9 oz

Display: LCD

Software: Windows XP SP3/Vista/7 and 8 (32 and 64-bit)

Baud Rate: 250000

Materials: Plastic

Alarm Note: User configurable audible, on-screen, email and text (SMS) alarms, Alarm Delay: A cumulative alarm delay may be set in which the device will activate the alarm (via LED) only when the device has recorded a user specified time duration of data, Audible Alarm Functionality: 1 beep per second for reading alarm above/below threshold

Input Type: Internal

Calibration: Digital Calibration through Software

Data Format: atm, °C, dew point, °F, inHg, K, kPa, m, mbar, mg/mL, mmHg, MPa, Pa, PSI, °R, %RH, Torr

Form factor: Wall Mount

Samples,Max: 10752 Samples, Interval Selectable 1 Sec to 24 hrs

Start Modes: At set date and time, Button Push, Immediate Start, Next Interval

Battery life: 5 yr, typical with reading interval of 1 min

Memory Modes: Yes

RF Frequency: 2.45 GHz

Configuration: Omega Data Logging Software, Windows PC

Pressure, Max: 1300 mBar

Pressure, Min: 250 mBar

RH Resolution: 0.1%, 12 bit

Time Accuracy: ± 1 minute/month

Band Frequency: 2.405 to 2.475 GHz

Data Interface: Wireless, USB

Calibration Date: Automated

Measurement Type: Pressure, Relative Humidity, Temperature

LED Functionality: Green LED blinks every 5 seconds to indicate unit is logging, Blue LED blinks every 15 seconds to indicate unit is in wireless mode, Red LED blinks every 1 second to indicate alarm condition

RF Frequency Note: 2.45GHz IEEE 802.15.4 ultra-low power wireless transceiver with fully bi-directional communication

Relative Humidity: 0 to 95% RH non-condensing

Supply Power Type: Battery

Current Resolution: Temperature: 0.01°C, Resistance: 0.001 Ω

Band Frequency Note: ISM band 2.405 to 2.48 GHz (channels 11 through 25) @ 250 kbps data rate

Data Interface Note: USB to mini USB, 250,000 baud for standalone operation or OM-CP-RFC1000- EXT required for wireless operation

Calibration Accuracy: Temperature: ± 0.5°C for 0 to 50°C, Pressure: ± 10 mbar, Relative Humidity: ± 3% RH

RH Measurement Range: 0 to 95% RH

Additional Features 1: Field Upgradeable

Battery Size and Type: Li-ion, 9V

Resistance Resolution: 0.001 Ω

Number of Measurements: 3

Temperature Resolution: 0.01 °C

Operating Temperature Note: -20 to 60°C, 0.002 to 100 psi

Operating Temperature, Max: 60 °C

Operating Temperature, Min: -20 °C

Temperature Measurement, Max: 60 °C

Temperature Measurement, Min: -20 °C