Width: 3.5 in

Height: 0.95 in

Length: 3 in

Weight: 4.1 oz

Display: LCD

Software: XP SP3/Vista/7 and 8 (32 and 64-bit)

Approvals: CE, FCC, IC, KCC

Baud Rate: 250000

Materials: Plastic

Alarm Note: User configurable audible, on-screen, email and text (SMS) alarms, Alarm Delay: A cumulative alarm delay may be set in which the device will activate the alarm (via LED) only when the device has recorded a user specified time duration of data, Audible Alarm Functionality: 1 beep per second for reading alarm above/below threshold

Input Type: External

Calibration: Digital Calibration through Software

Form factor: Wall Mount

Samples,Max: 32256 Samples, Interval Selectable 1 Sec to 24 hrs

Sensor Type: Voltage Sensor

Start Modes: Delayed Start, Immediate Start

Battery life: 3 yr, typical with reading interval of 15 min

Memory Modes: Yes

RF Frequency: 2.45 GHz

Configuration: Omega Data Logging Software, Windows PC

Logging Modes: Fixed interval

Time Accuracy: ± 1 minute/month

Band Frequency: 2.405 to 2.475 GHz

Data Interface: Wireless, USB

Conversion Time: 150 milliseconds

Nominal Voltage: 2.5V

Calibration Date: Automated

Measurement Type: Voltage

LED Functionality: Green LED blinks every 5 seconds to indicate unit is logging, Blue LED blinks every 15 seconds to indicate unit is in wireless mode, Red LED blinks every 1 second to indicate alarm condition

RF Frequency Note: 2.45GHz IEEE 802.15.4 ultra-low power wireless transceiver with fully bi-directional communication

Relative Humidity: 0 to 95% RH non-condensing

Supply Power Note: Ultralife 9V lithium battery included; user replaceable

Supply Power Type: Battery

Band Frequency Note: ISM band 2.405 to 2.475 GHz operation (channels 11 through 25) @ 250 kbps data rate

Data Interface Note: USB to mini USB, 250,000 baud for standalone operation or OM-CP-RFC1000- EXT required for wireless operation

Overload Protection: ± 50 Volts for 2 seconds

Calibration Accuracy: Voltage: 0.1 mVdc

Battery Size and Type: Li-ion, 9V

Number of Measurements: 1

Voltage Measurement Range: -3 to +3 Vdc

Operating Temperature, Max: 60 °C

Operating Temperature, Min: -20 °C