Input Sampling Period: 1 second 

External Contact Input: Solid state switch closure, logic driven voltage output, or open/closed mechanical switch 

Solid State Switch Closure:

  Input Low: < 10 KΩ; 

  Input High: > 300 KΩ

Logic Signal Level:

  Logic 0: < 0.4 V DC

  Logic 1: > 2.5 V DC 

Internal Weak Pull-Up: 100 KΩ

Input Range: 0 to 3.6 V 

User Connection: 24 AWG wires, 2 leads: white(+), black(-) 

Operating Temperature Range: -40° to 75°C (-40° to 167°F) 

Time Accuracy: ±4 seconds due to potential clock differences between the sensor and the station. Note that longer logging intervals can result in the maximum error. 

Overall Cable Length: 6.5 m (21.3 ft.) 

Length of Smart Sensor Cable: 50 cm (1.6 ft.) 

Weight: 200 g (7.06 oz) 

Number of Data Channels: 2 

Bits per Sample:

  12 bits for channel logging runtime as percent 

  16 bits for channel logging runtime in seconds

What's In The Box

  RX Runtime Smart Sensor with 6m cable

  2 wire nuts

Measures the percent ON of any AC-powered device with an AC current switch, and time ON (closed) of contact closures. Ideal for equipment runtime monitoring, boiler efficiency monitoring, pump monitoring, and engine monitoring. This sensor is compatible with HOBO RX monitoring stations.