인증된 전문가에게 직접 연결
인증된 전문가에게 직접 연결
Input Sampling Period: 1 second
External Contact Input: Solid state switch closure, logic driven voltage output, or open/closed mechanical switch
Solid State Switch Closure:
Input Low: < 10 KΩ;
Input High: > 300 KΩ
Logic Signal Level:
Logic 0: < 0.4 V DC
Logic 1: > 2.5 V DC
Internal Weak Pull-Up: 100 KΩ
Input Range: 0 to 3.6 V
User Connection: 24 AWG wires, 2 leads: white(+), black(-)
Operating Temperature Range: -40° to 75°C (-40° to 167°F)
Time Accuracy: ±4 seconds due to potential clock differences between the sensor and the station. Note that longer logging intervals can result in the maximum error.
Overall Cable Length: 6.5 m (21.3 ft.)
Length of Smart Sensor Cable: 50 cm (1.6 ft.)
Weight: 200 g (7.06 oz)
Number of Data Channels: 2
Bits per Sample:
12 bits for channel logging runtime as percent
16 bits for channel logging runtime in seconds
What's In The Box
RX Runtime Smart Sensor with 6m cable
2 wire nuts