For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

Polimaster PM1703M 개인 방사선 검출기

ModelPM1703M
원산지EU
문의하기
안전한 결제
품질 보장
간편 교환 및 반품
배송 가능
- Detector:  gamma CsI(Tl)
- Sensitivity:
+ for 137Сs, no less 85 (s-1)/(μSv/h)  (0.85 (s-1)/(μR/h))
+ for 241Am, no less 100 (s-1)/(μSv/h) (1.0 (s-1)/(μR/h))
- Energy range:  gamma 0.033 – 3.0 MeV
- Dose Rate:   gamma 0.01 – 99.99 μSv/h  (1 – 9999 μR/h)
- Dose: X
- Accuracy:  ±30% (in range 0.1 – 70 μSv/h  (10 – 7000 μR/h) )  (at 137Cs)
- Response time:  0.25 s
- Radionuclide identification using  Bluetooth communication with external Pocket PC or smartphone:
+ Special nuclear materials (SNM): X
+ Medical radionuclides: X
+ Naturally occurring radioactive  materials (NORM) : X
+ Industrial radionuclides: X
- Standards compliance:   ITRAP/IAEA requirements, ANSI N42.32, ANSI N42.33(1),  IEC 62401
- Alarm type:  visual, audio, vibration
- Data recording:  1000
- Environmental protection:   IP65
- Drop test on concrete floor:  1.5 m (4.9 ft)  0.7 m (2.3 ft) without cover
- Power supply:  one AA battery
- Battery life time:  up to 1000 hours
- Operating temperature:   -30°C to 50°C (-22°F to 122°F) 
- Size (without cover):  87 x 72 x 40 mm  (3 3/8 x 2 7/8 x 1 5/8)
- Weight:(without cover) 180 g (6.35 oz); (with cover) 220g (7.75 oz)
- Low battery warning:  LCD
- Overload indication:  gamma OL
- PC Communication:  IRDA
 

 The tiny personal radiation detectors designed to detect and locate the minimum amounts of the radioactive and nuclear materials. The instrument provides two operating modes: search for the gamma radiation sources and evaluation of the radiation level in mSv/h or mR/h.

Polimaster Personal Radiation Detectors PM1703M are designed to detect and locate even the slightest traces of the radioactive and nuclear materials. The instruments two operating modes enable the user both search for gamma radiation sources based on the intensity of the emitted radiation and evaluate the radiation level. 
The PM1703M perform the following functions: 
Detect gamma radiation sources, even if they are shielded; 
Alert the user of the presence of a radiation source through audible, visual and vibrating alarms;
Record and store data for up to 1000 events in the instruments non-volatile memory; 
Transmit all recorded data to a PC via IR channel for the data processing and analysis.