For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0

Qualistar+ CA 8336: Easy and in-depth power quality analysis in the field

2025년 07월 21일 09시 28분 59초

In many electrical systems today, monitoring and detecting problems such as voltage drops, harmonic distortion, phase imbalance or flicker events is indispensable. Especially in manufacturing plants, data centers or commercial buildings where electronic equipment operates at high intensity, ensuring stable power quality not only helps to operate efficiently but also prolongs the life of the equipment.

Qualistar+ CA 8336, a 3-phase power quality analyzer from Chauvin Arnoux (France), is the solution for electrical engineers and maintenance technicians looking for a device that can both measure quickly and provide complete data for timely troubleshooting, right on site.

The device is not only for single parameter testing

Unlike conventional electrical measuring devices, Qualistar+ CA 8336 not only measures basic parameters such as voltage, current, frequency but also extends to more than 2,000 different analytical parameters, helping users see the overall picture of the system's power quality.

In-depth harmonic analysis

A highlight of this device is the ability to record and analyze harmonics up to level 50. This is an extremely important factor for factories using inverters, UPS or large power electronic equipment, where high harmonics can easily cause disturbances and energy loss.

Fast error detection and full data retention

Qualistar+ CA 8336

The Qualistar+ CA 8336 supports recording of 4,000 voltage events in the same measurement campaign, making it easy for users to detect transient faults, phase loss events or short-term voltage dips — faults that are often difficult to detect when measuring only for a short time or periodically.

All data is displayed in the form of graphics, figures and intuitive waveforms on the 7" TFT color screen, making it easy to operate even in the field.

No need for computer, still can analyze on the spot

One of the outstanding strengths of the CA 8336 is the ability to analyze right on the device, without having to export data to a computer. With an intuitive, easy-to-use menu divided into each usage category (measurement, recording, analysis...), the device helps save processing time, especially in production environments that require quick decision making.

Supports simultaneous measurement of multiple complex signal types

- CA 8336 is capable of simultaneously measuring:

- Voltage / current (3 phase + neutral)

- Active, reactive, apparent power

- Power factor (cos φ), frequency

- Total harmonic distortion (THD) for voltage and current

- Temperature (with optional probe)

- 4–20 mA current signal from sensor

Wide application in electrical system

The versatile measurement capabilities make the device suitable for a wide range of systems: from main power distribution cabinets, generators, transformers, to high power consuming devices such as motors, HVAC, industrial lighting systems...

Durable design, suitable for construction site conditions

Qualistar+ CA 8336 is designed to operate stably in industrial conditions:

Large color display, easy to read even when working outdoors

Rubber case is shockproof, light dustproof

Operates on AC power or rechargeable battery, up to 13 hours of use

8 GB internal memory, supports SD card and USB for quick data backup

In-depth software integration and automated reporting support

After measurement, users can export the data and use Chauvin Arnoux's dedicated software to:

Analyze waveforms and trend charts

Filter harmonics and evaluate in real time

Generate power quality reports according to EN50160, IEC 61000-4-30 or internal requirements

This feature is especially useful for businesses that need to periodically report, compare power quality or serve power source disputes with third parties.

Conclude

If you are looking for a device that not only measures but also helps you understand the electrical system more clearly to make decisions, then the CA 8336 is an option not to be missed. 

📞 Contact EMIN for detailed technical advice and receive the latest offers from Chauvin Arnoux.

관련 뉴스

Why is the 6H/6g tolerance pair the most common in mechanical drawings?
2026년 06월 19일 15시 03분 48초

Flip through detailed drawings or standard bolt documentation, and the designation 6H/6g appears very frequently. The external thread is machined slightly smaller than the nominal size, while the internal thread maintains its correct tolerance range.

How do metric and inch thread gauges differ?
2026년 06월 19일 09시 30분 37초

How do metric and inch thread gauges differ? Learn how to distinguish M10×1.5 from 1/2"-13 UNC, thread pitch, thread crest angle, and how to choose the correct GO/NOGO gauge to avoid damaging parts.

The Voltage Measures at 220V, but the Equipment Still Operates Abnormally?
2026년 06월 18일 11시 00분 42초

A measured voltage of 220V does not necessarily mean the system is operating stably. When the multimeter display and actual equipment behavior begin to contradict each other, the inspection should be expanded to include load conditions, electrical contact quality, and waveform characteristics rather than repeatedly performing the same voltage measurement.

혜택 소식 받아보기

대량 할인, 도매 가격 업데이트 및 신제품 소식을 이메일로 받아보세요.

구독하면 당사의 서비스 이용약관개인정보 처리방침에 동의하는 것으로 간주됩니다.

빠른 지원

인증된 전문가에게 직접 연결