RCBO and RCCB are both leakage current protection devices commonly used in today's civil power grids, to enhance user safety. However, there are still notable differences between the two types.

If RCCB is specialized in detecting and disconnecting when there is a leakage current, RCBO integrates overcurrent and short circuit protection, providing more comprehensive protection. The following article from EMIN will help you better understand the difference between RCBO and RCCB in a specific and easy-to-understand way.

Explore the operating structure and specifications of RCCB

RCCB (Residual Current Circuit Breaker) is a circuit breaker specifically used to protect against leakage current, often installed in civil electrical systems to increase safety. The operating mechanism of this device is based on the ability to detect leakage current through a component called RCD - a residual current sensor in the shape of a toroidal coil, surrounding the phase wire and neutral wire. When leakage current appears, the current difference between phase and neutral will cause the coil to heat up, activate the thermal relay and command the circuit to be cut off. RCCB is currently commonly produced in two versions: 2-pole type for 1-phase electricity and 4-pole type for 3-phase electricity. In terms of appearance, the device is in the form of a miniature circuit breaker with a control lever and a leakage current test button integrated right on the body.

Some typical specifications of RCCB include:

Leakage detection threshold: 10mA, 30mA, 100mA and 300mA

Short circuit breaking capacity: 6kA and 10kA

Rated current: 16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 100A

Structure and specifications of RCBO - Multi-function integrated protection device

RCBO (Residual Current Circuit Breaker with Overcurrent protection) is a new generation of anti-shock device, integrating three functions at the same time: leakage current, overload and short circuit protection. In essence, RCBO is a combination of RCCB and MCB in the same device, helping to optimize space and simplify the electrical system. The external appearance of RCBO is often similar to a shrimp circuit breaker, equipped with a lever according to the number of poles, along with a leakage current test button like on RCCB.

Inside the RCBO, two key components, the RCD circuit (residual current detection) and the ARC divider (overcurrent and short circuit protection), play a role in detecting faults. As long as one of these two mechanisms is activated, the RCBO will immediately cut off the circuit to protect equipment and people. Unlike RCCB, RCBO has an additional ARC divider to take on the function of cutting off when there is a fault in the current.

Typical specifications of RCBO include:

Leakage current detection threshold: 10mA, 30mA, 100mA, 300mA

Short circuit current capacity: 6kA

Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A, 63A

Functional comparison between RCCB and RCBO

The core difference between RCCB and RCBO lies in the scope of protection. While RCCB is only specialized in detecting and cutting off current when an electric leakage occurs, RCBO is a multi-purpose device that combines both anti-shock and overload and short circuit protection functions. As a result, RCBO provides more comprehensive protection for the electrical system. 

Both devices are based on the principle of comparing the incoming and outgoing currents to detect leakage current. The internal RCD circuit will detect the current imbalance in the circuit. When the residual current exceeds the safety threshold, the circuit will automatically be cut off to prevent electrical risks.

For RCBO, overload and short circuit protection features are integrated similar to MCB, through thermal and magnetic sensor mechanisms. Thanks to that, RCBO not only prevents electric shock but also disconnects the circuit when there is a problem with the current.

See more devices at: EMIN electrical circuit breaker

Difference in application of RCCB and RCBO

In terms of application, both RCCB and RCBO play a role in protecting the safety of electrical systems, especially in areas with potential risks of electrical leakage such as toilets, kitchens, factories, or places with high humidity. However, each type is suitable for specific usage situations:

Leakage current 10mA, 30mA: Usually used for civil and commercial works to ensure personal safety.

Leakage current 100mA: Applied for fire prevention and electrical short circuit prevention purposes in larger areas.

300mA leakage current: Installed in industrial electrical cabinets where the entire system is required to be protected.

RCBO with its diverse protection capabilities and wider rated current is gradually becoming the optimal choice for both the main electrical system and each individual branch. Unlike RCCB, RCBO can operate independently, without the need for an additional MCB in front.

In addition, RCBO is especially suitable for separate protection of large-capacity equipment such as air conditioners, welding machines, solar power systems, inverters, escalators or elevators. Meanwhile, RCCB is mainly arranged in the main electrical circuit or fixed areas requiring basic anti-shock.

관련 뉴스

EMIN Becomes an Official Distributor of ZEISS in Vietnam Starting July 2026
2026년 07월 24일 15시 35분 27초

Starting in July 2026, EMIN officially became an Authorized Distributor of ZEISS in Vietnam. With a history spanning more than 175 years, ZEISS is recognized as one of Germany's technology companies and a global pioneer in the fields of optics and optoelectronics. The company provides advanced solutions for industrial manufacturing, scientific research, healthcare, semiconductor production, and quality assurance.

How Does Fluke Help Factories Detect Hard-to-Spot Electrical Risks?
2026년 07월 24일 14시 23분 04초

The more high-capacity machinery a factory houses and the more complex its power supply network becomes, the harder it is for routine checks such as voltage measurements or visual inspections of electrical cabinets to fully reflect the safety status.

Which products are tested using a -40°C to +150°C thermal shock chamber?
2026년 07월 22일 14시 45분 25초

Automotive circuit boards, sensors, modules, and plastic components can all experience issues after repeated transitions between cold and hot environments. A thermal shock chamber operating from -40°C to +150°C enables the replication of these temperature fluctuations under controlled testing conditions.

Does thermal shock cause damage to electronic components?
2026년 07월 22일 10시 40분 49초

An electronic component may operate stably under constant temperature conditions yet fail after repeated rapid transitions between hot and cold. The issue typically stems not from a specific temperature level, but rather from the rate of temperature change and the number of hot-cold cycles

The rigorous standards behind a multi-million-dollar MRI suite
2026년 07월 21일 14시 54분 01초

An MRI system may be correctly installed and fully connected to the power supply, yet still encounter issues if the surrounding environment fails to meet technical specifications. Electromagnetic interference, RF shielding, power quality, grounding, temperature, humidity, and particulate levels are all factors that may require assessment, depending on the facility's design and the manufacturer's requirements.

혜택 소식 받아보기

대량 할인, 도매 가격 업데이트 및 신제품 소식을 이메일로 받아보세요.

구독하면 당사의 서비스 이용약관개인정보 처리방침에 동의하는 것으로 간주됩니다.

빠른 지원

인증된 전문가에게 직접 연결