인증된 전문가에게 직접 연결
인증된 전문가에게 직접 연결
Parameters: pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation)
pH:
Range: -2.000 to 20.000 pH
Resolution: 0.1, 0.01, 0.001pH
Accuracy: ±0.002 pH
Calibration Points: Up to 6
Standard Customization: Yes
Calibration Reminder: Yes
Standard Recognition: NIST, GB, DIN, USA, MERK, JIS buffers
Slope Limit: Yes
mV/ORP:
Range: -2000.00 to 2000.00 mV
Resolution: 0.1, 0.01 mV
Accuracy: ±0.1 mV or ±0.03% of reading whichever is greater
EH ORP Mode: Yes
ORP Calibration Points: 1 custom point (relative mV)
pX:
Range: -2.000 to 20.000 pX
Resolution: 0.1, 0.01, 0.001 pX
Accuracy: ±0.002 pX
Calibration Points: Up to 6
ISE:
Range: 1.000e-9 to 9.999e+9
Units: mol/L, mmol/L, g/L, mg/L, μg/L, ppm, ppb
Resolution: Up to 4 significant digits
Accuracy: ±0.3%
Calibration Points: Up to 6
Conductivity:
Range: 0.000 μS/cm to 2000 mS/cm
Resolution: 0.001 μS/cm minimum, various with range selection
Accuracy: ±0.5% FS
Reference Temperature: 5, 10, 15, 18, 20, 25 ºC
Calibration Points: Up to 5
Calibration Reminder: Yes
Standard Recognition: 10 μS/cm, 84 μS/cm, 500 μS/cm, 1413 μS/cm, 12.88 mS/cm; 146.5μS/cm, 1408μS/cm, 12.85mS/cm, 111.3mS/cm
Resistivity:
Range: 5.00 Ω·cm~100.0 MΩ·cm
Resolution: 0.01 Ω·cm minimum
Accuracy: ±0.5% FS
TDS:
Range: 0.000~1000 ppt
Resolution: 0.001 ppm minimum, changed with range
Accuracy: ±0.5% FS
Salinity:
Type: NaCl
Range: 0.0~80.0 ppt
Resolution: 0.1ppt
Accuracy: ±1ppt
Dissolved Oxygen Concentration - Polarographic:
Range: 0.00 to 99.99 ppm
Resolution: 0.01 ppm
Accuracy: (0.00~50.00)ppm,±0.10ppm; (50.0~99.99)ppm,±0.50ppm
Calibration Reminder: Yes
Calibration Points: Air-saturated water or zero point
Barometric Compensation: Yes
Manual Salinity Factor Correction: Yes
% Saturation - Polarographic:
Range: (0.0 to 600)%
Resolution: 0.1%
Accuracy: ±2.0%
Temperature:
Range: -10 to 135 ºC, 14 to 275 ºF
Unit: ºC, ºF
Resolution: 0.1
Accuracy: ±0.1ºC
Measurement:
Reading Mode: Auto Read (Fast, Medium, Slow), Timed, Continuous
Reading Prompts: Reading, Stable, Locked
Temp. Compensation: ATC, MTC
Data management:
Data Storage: 1000 Groups
GLP Features: Yes
Log Management: Yes
Inputs:
pH Electrode: BNC(Q9)
DO with Temp. Probe: 4-pin aviation connector
Conductivity with Temp. Probe: 5-pin aviation connector
Outputs:
USB: USB 2.0 flash memory device, PC, scanner,
RS 232: printer, auto-sampler
Display options:
Backlight: Yes
Auto Shutdown: 1~60 min, off
IP Rating: IP54
Date and Time: Yes
General:
Power: AC Adapter, 100-240V AC input, DC24V output
Dimensions: 220×195×68 mm
Weight: 950g (2.09 lb)
Includes:
E-301-QC pH 3 in 1 composite electrode
DJS-1VTC EC electrode
DO-958-Q polarographic DO electrode
NIST pH standard solution(4.01, 7.00, 10.01) ,50ml/vial
1413μS/cm EC standard solution, 50ml, 1 vial
REX-6 electrode stand
Touch pen