Sensor: analog Hall sensors

Nominal width: DN 8..25

Process connection: female thread G 1 /4..G 1

Metering range: 0.5...60 l/min for details see see table "Ranges" 

Pressure loss: 1.1...3.5 bar at Qmax.

Qmax.: to 80 l/min

Tolerance: ±3 % of full scale value

Pressure resistance: PN 200 bar, optionally PN 500 bar

Media temperature: -20..+85 °C optionally -20..+120 °C

Ambient temperature: -20..+70 °C

Media:  oils

Wiring: see section "Wiring"

Supply voltage: 18..30 V DC

Power consumption: < 1 W

Outputs: transistor output "push-pull" (resistant to short circuits, and reversal polarity protected) lout = 100 mA max.

Display: yellow LED (On = Normal / Off = Alarm / rapid flashing = Programming)

Ingress protection: IP 67

Electrical connection: for round plug connector M12x1, 4-pole

Materials medium-contact

Brass construction: CW614N nickelled, CW614N, 1.4310, hard ferrite, NBR

Stainless steel construction: 1.4571, 1.4404, 1.4310, hard ferrite PTFE-coated, FKM

Non-mediumcontact materials: CW614N nickelled

Weight: see table "Dimensions and weights"

Conformity: CE

Installation location

Standard: horizontal inwards flow; other installation positions are possible; the installation position affects the metering and switching range.