For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

Senseca LABO-HR2E-IPSD 유량 트랜스미터 (50...300l/min, 0/4...20 mA)

ModelLABO-HR2E-IPSD
문의하기
안전한 결제
품질 보장
간편 교환 및 반품
배송 가능

Full scale value can be programmed (teaching possible)

Sensor: analog Hall sensor

Nominal width: DN 32 / 40 / 50

Process connection: female thread G 1 1/4..G 2 (further process connections available on request)

Metering range: 50....300 l/min for details see table "Ranges"

Pressure loss: ~ 1 bar at Qmax

Qmax.: up to 300 l/min

Measurement accuracy: 8% of full scale value

Pressure resistance: PS 200 bar

Medium temperature: -20..+85 °C, optionally -20..+120 °C

Ambient temperature: -20..+70 °C

Media: water

Wiring: see section "Wiring"

Materials medium-contact

Brass construction: CW614N nickelled, CW614N, 1.4305, 1.4310, hard ferrite,

Stainless steel construction: 1.4571, 1.4310, hard ferrite

Materials, non medium-contact: CW614N nickelled

Supply voltage: 18..30 V DC

Power consumption: < 1 W

Output:  Current output 4..20 mA (alternatively 0..20 mA)

Max. load 500 Ohm

Display: yellow LED (On = Normal / Off = Alarm / rapid flashing = Programming

Electrical connection: for round plug connector M12x1, 4-pole

Ingress protection: IP 67

Weight: see table "Dimensions and weights"

Conformity: CE

Installation location

Standard: horizontal inwards flow; other installation positions are possible; the installation position affects the display, metering and switching range.