Coils are one of the structural components of electrical and electronic equipment, so checking them regularly is necessary. If there is a problem with the coil, the device's performance can be affected, even leading to serious damage. Therefore, checking your coils periodically will help ensure EMIN will share some simple and easy-to-implement ways for you to effectively and easily check your coils yourself.

Check coil pulse

Normally, the wires in the coil are insulated with a specialized coating, but over time, the insulation resistance can decrease, causing a short circuit. 

The pulse testing technique works by applying a pulsed voltage to the coil, then recording the response waveform. This waveform will be compared with a sample waveform from a well-functioning motor to detect any errors or damage. In this way, it is possible to determine the condition of the coil and draw more accurate conclusions

Changes in the coil's response waveform are determined by three main factors: the inductance value (L), the resistance value (R) of the coil, and the capacitance value (C) of the motor. Judgment method through area comparison is a commonly used way to measure the difference between the waveforms of normal and defective parts. 

Some modern devices also have the ability to automatically quantify this response waveform. The inductance, resistance and capacitance values ​​of the coil play an important role in calculating and evaluating waveform changes, helping to accurately determine the condition of the motor.

Measure insulation resistance

Insulation resistance measurement evaluates the insulation condition of the windings, especially useful in testing motor windings. When the insulation of the coil is degraded, the risk of electric shock or short circuit increases significantly. 

Checking the insulation condition of the coil is essential to ensure equipment safety. If the measurement results show that the resistance of the coil reaches infinity, it can be concluded that the insulation is still guaranteed.

Conversely, if the resistance is 0 Ω, this indicates that the insulation has been compromised and is likely to cause a problem. To achieve more accurate results, you should use a device with a contact test function, which makes it easier to check for damaged wires, avoiding erroneous conclusions during the test.

Reference: Hioki ST5520 insulation resistance tester

Ability to withstand testing

As well as measuring insulation resistance, withstand voltage testing is an important test method to ensure the coil is capable of withstanding the operating voltage without insulation problems. Sometimes, we can confuse these two techniques because they both aim to ensure safety, prevent electric shock and fire. However, each technique has a different approach and purpose.

Insulation resistance testing focuses on measuring resistance values ​​to detect defects in insulation. Withstanding voltage testing goes further, using a specific voltage level, usually determined by the product's safety standards, to test whether a failure occurs when the coil is subjected to high voltage or not. From there, we can evaluate the resistance of the insulation and ensure that the device will not have problems when operating in practice.

Measure the inductor

Inductance represents the ability to create an induced electromotive force when the current changes. It can be simply understood that it is like a resistance to alternating current. Coils designed to produce inductance are often called inductors, and they come in many different types. Some coils do not use a magnetic core, but only air or non-magnetic materials. Meanwhile, other coils have cores made from magnetic materials such as ferrite, which makes their inductance depend on the current flowing through them.

Inductors with magnetic cores also have the phenomenon of self-resonance, when the inductance and parasitic capacitance of the core create a resonant frequency, called the self-resonant frequency. To accurately measure the inductance of the coil, specialized measuring equipment such as an LCR meter should be used. However, it is important that the L and Q measurements be made at a frequency low enough relative to the self-resonance frequency to ensure the highest accuracy.

Coil inspection cannot be overlooked in electronic circuits, especially when checking product quality or during equipment maintenance and repair.

Product reference: HIOKI IM3536 LCR meter

Conclude:

Above are common methods to effectively check coils. If you find it useful, please follow EMIN Fanpage to update more information!

관련 뉴스

Why is the 6H/6g tolerance pair the most common in mechanical drawings?
2026년 06월 19일 15시 03분 48초

Flip through detailed drawings or standard bolt documentation, and the designation 6H/6g appears very frequently. The external thread is machined slightly smaller than the nominal size, while the internal thread maintains its correct tolerance range.

How do metric and inch thread gauges differ?
2026년 06월 19일 09시 30분 37초

How do metric and inch thread gauges differ? Learn how to distinguish M10×1.5 from 1/2"-13 UNC, thread pitch, thread crest angle, and how to choose the correct GO/NOGO gauge to avoid damaging parts.

The Voltage Measures at 220V, but the Equipment Still Operates Abnormally?
2026년 06월 18일 11시 00분 42초

A measured voltage of 220V does not necessarily mean the system is operating stably. When the multimeter display and actual equipment behavior begin to contradict each other, the inspection should be expanded to include load conditions, electrical contact quality, and waveform characteristics rather than repeatedly performing the same voltage measurement.