Number of shaking platforms: One-tier

Shaking motion/Shaking width/Door type: Switchable Reciprocal/Orbital shaking, 10 to 50 mm (stepless), Double swing door

Temperature range (*1): +4℃ to +60℃

Temp. control accuracy (*2): ±0.3℃ to ±1.0℃

Speed range (*3): 30 to 250 r/min

Platform size/Capacity: 800 × 600 mm (Max. inside height: 601 mm), Erlenmeyer flask 500 mL × 32.5 L × 6

Maximum load: Approx. 17 kg (Platform not included)

Ambient temp. range (*1): +5℃ to +35℃

Heating/Cooling method: Heater 800 W/Compressor 125 W

Program functions: Number of stored programs: 4 programs, number of steps: 9 steps (per program) Setting contents (*4): Temperature, shaking speed, and time (per step) with weight function (time setting range: 00 h 00 min to 99 h 59 min)

Safety devices/functions: Leakage breaker 15 mA (15 A for overcurrent protection), High temperature safety device, High temperature cut circuit for compressor, Motor current limiter, Motor overload protection, Over-voltage protection, Fuse, Filter check function, Shaking stop function upon abnormal vibration detection, Self-diagnosis function for temperature sensor error, Nonvolatile memory error, Alarm of abnormal sample temp. (Set as desired),Detecting the door opening and closing, Breaking device when motor runaway

Other functions (*5): Eco-Drive function, Automatic lighting of the chamber light, Communication holes in the chamber (2 holes), Automatic drying of condensation water (*6)

Dimensions (W × D × H): 1327 × 835 × 1256 mm (with top board installed)

Weight: Approx. 328 kg

Power supply: AC100V/AC220-240V/12A built-in down transformer

Standard accessories: Universal shaking platform MT-8060A ×1 pc, Vibration absorbing pad× 4pcs, Spacer × 4 pcs

(*1)If the product is to be used at a temperature setting of +10.0℃ or lower, the ambient temperature should be +30℃ or lower. The specifications of this product are the performance values based on themeasurement method specified by our company.

(*2)Temperature change immediately after the defrosting function is activated is not included.

(*3)Shaking speed for both reciprocal/orbital.

(*4)The weight function is a function that allows shaking to begin after the inside of the chamber reaches a set temperature. This product does not have a temperature gradient (tilt) function.

(*5)Transmission output signal (analog signal) 1 to 5 V and alarm output signal (DCV) are also available by special order.

(*6)Depending on usage conditions, automatic drying may not be able to keep up and manual drainage may be required.