Temperature range (*2)(Thermominder): 5℃ above RT to +70℃ (Preset/Current temp. displayed simultaneously in the SDN/EXN switch. Switchable Preset/Current temp display in SM.)

Temp. control accuracy (*3)(Thermominder): ±0.1℃ to 0.3℃

Temperature memory(Thermominder): 3

Temperature memory(Thermominder): 1

Timer (*4)(Thermominder): -

Other functions(Thermominder): Buzzer notification when preset temp. is reached, Automatic tuning

Heater(Thermominder): 800 W

Safe devices/protections(Thermominder): Circuit protector, Fuse, Dry-heating protection with float, Heater protection cover (SM-05N), Sensor error, Short circuit, High/Low temp. Sample protection,Water level alarm, Non-volatile memory error, Automatic tuning error, Alarm setting error, Switchable Automatic/Manual recovery when power failure

Power supply(Thermominder): AC 100 V/8.5 A

Shaking method(Personal): Reciprocal shaking, Shaking speed: 20 to 160 r/min (displayed digitally), Shaking width: 10 to 40 mm (Stepless variable, Default 30 mm)

Platform dimensions(Personal) : 220 × 310 mm

Other functions(Personal): Elapsed time indicator (0.1 to 999.9 h, with Automatic reset) × 1 , Service outlet for Thermominder ×1

Bath inside dim.(W×D×H)/volume(Personal): 235 × 430 × 140 mm, Approx. 11 L (80% Water level) (*6)

Power supply(Personal): AC100V/0.5A /Max.9A with SDN (Need a step-down transformer)

Standard accessories(Personal): Spring net Shaking Platform × 1 pc, Clamp Spacer × 1 pc

Dimensions (W×D×H)/weight: 300 × 495 × 336 mm, Approx. 19 kg


(*1)Can be combined with SJ-07N and SX-10N.

(*2)Max. temp. may not be reached when the optional Hood is not used or depending on the usage conditions.

(*3)The value under the conditions of RT (25℃), AC 100V/50 Hz, 80% Water level, Preset temp. 37℃, and No heat load. Only for EXN Measured value.

(*4)Each setting range is 1 min to 99 h 59 min.

(*5)This also serves as a packing box whereas it is not used together with

the Personal-11 Set.

(*6)The proper volume is 7 L to 9 L when shaking with the capacity (max. number) such as Centrifuge tubes and max. 500 mL of Erelnmeyer flasks at 120 to 160 r/min.